18
SL6+ v.3.30 EN
Introduction
Parameters
unique for
SafeLine
CONNECT
Certain settings can only be congured with the SafeLine CONNECT
app. Below is a list of functions unique for the app and where to nd
them. Tex t in red = SafeLine CONNECT paths.
Test alarm interval (per day/hour)
Conguration -> ID- and telephone numbers -> Test alarm -> Test
alarm interval
• Adjustable interval, either per day or per hour, between alarm
test. If both values are set to 0, alarm tests are off.
View current GSM operator in the SafeLine CONNECT app
Main unit diagnostics -> Operator name
• Command that lets you view your current operator. Not available
= GSM net not available. Unit busy = unit is busy with ongoing call.
Congure number of outgoing call retries
Conguration -> Calls -> Max outgoing call retries
• Max Outgoing Call Retry – can be set from 4-12 tries. 12 = Default.
Applies to all types of calls excluding the test dialogue in the Safe-
Line CONNECT app/SL Pro (2 calls).
Emergency button check (requires built-in magnet button)
In- and outputs -> Relay 1/2 -> Emergency button check
• During emergency but ton check, the relay is activated for
3 seconds, waiting for emergency button signal. If main unit does
not receive message, a ”stuck button” alarm will be sent.
“Battery test active” function
Main unit diagnostics -> Battery test active
• Test function shown in the SafeLine CONNECT app, to view if a
battery test is in progress.
Emergency light car Top/Pit
Conguration -> Voice stations -> Emergency light car top/pit
• Emergency Light Top/Pit (On/Of f), Default = Off. If activated, the
emergency light turns on for voice stations marked Top/Pit during
mains power failure.
Fallback alarms
Conguration -> System -> Fallback -> PSTN/GSM Fallback
• Priority PSTN/GSM. Default = disabled. Choose which interface
is prioritized and activates transmission of LMS correlating to the
Fallback function.
• Fallback alarm delay: 1 - 10 minutes.
Dual test alarms (On/Off), Default = Off. When activated, both
PSTN and GSM interfaces will send test alarms.
Disable test call through cong. handset:
Conguration -> Calls -> Cong-handset test call
• "Cong-handset test call" (On/Of f). Default = On. 0 = turns of f
outgoing calls through handset.