3
SL6+ v.3.30 EN
Introduction
SafeLine SL6+
Power Supply voltage: 12 VDC, current drain nominal 15 mA
Inputs 10-30 VDC, 5 mA, optically isolated
Pictogram outputs Max 100 mA, 24 VDC, transistor outputs, open collector
IP code COP: IP00
COP2, Surface- or ush mounted units: IP40
To reach safety level IP4X, suitable additional protection have to be
installed onsite.
Max cable length 0,22 mm² cable: 100 m
0,75 mm² cable: 250 m
Operating temperature +5 C° — 40 C°
Air humidity 30% — 90% RH
Technical data voice station
Power Supply voltage: 230 VAC, 50 Hz, min: 6,4 W, max: 9,4 W
Battery Battery voltage: 12 VDC lead bat tery
Capacity: 1,2 Ah
Charge: 13,65 VDC, max. 200 mA
Emergency light Emergency light output: 12 VDC max 500 mA
Emergency signal Acoustic emergency signal output: 12 VDC max 200 mA
Inputs 10-30 VDC, 5 mA, optically isolated
Antenna connector SMA (female)
Size SL6+: 241 x 160 x 47 mm (L x W x H)
SL6+ Mini: 244 x 113 x 52 mm (L x W x H)
Weight 1.7 kg
Relay outputs Max 1 A/30 VDC. volt free relay outputs.
IP code IP20
Audio les Format WAVE-8 or 16kHz, 16 bit mono, max 16 sec/le
Bluetooth Bluetooth 4.0
BLE 2,4 GHz, (2402 2480 MHz), Max 2dBm
Operating temperature +5 C° — +40 C°
Air humidity 30% — 90% RH
Interface Boards *SL6-GSM-BOARD:
- Micro SIM, 15 x 12 x 0,76 mm
- Supports 2G
- Requires SW 3.40 or later
*GSM-R/EGSM900/GSM1800
- RF output power: Class 4 [2 W] for GSM-R/EGSM-R/EGSM900,
Class 1 [1 W] for GSM1800
*IF-BOARD-4G
- Micro SIM, 15 x 12 x 0,76 mm
- Suppor ts 2G, 3G and 4G
- Requires SW 4.45 or later
Technical data main unit