SL6+ v.3.30 EN
Conguration
Alarm status outputs
• Relay will be activated when set time is reached.
• Relay will be deactivated when emergency
call ends.
Battery failure
• Relay will be activated when the battery test has failed.
• Relay will be deactivated by pressing the reset button.
Pictogram yellow (only relay 1)
• Relay will be activated when the alarm button is pressed (yellow
pictogram).
• Relay will be deactivated when the reset button is pressed or if
alarm centre presses “5”.
Pictogram green (only relay 2)
• Relay will be activated when the call is acknowledged (green
pictogram).
• Relay will be deactivated when the call is disconnected.
Activate with DTMF 8 (only relay 1)
• Relay will be activated for 5 seconds when DTMF “8” is pressed.
Activate with DTMF 9 (only relay 2)
• Relay will be activated for 5 seconds when DTMF “9” is pressed.
Manual reset
• Relay will be activated when set time reached.
Emergency call failure
• Relay will be activated when the emergency call failed after 12
attempts, ”Emergency Call Fail”.
System failure
• Relay will be ac tivated when power (230 VAC) and PSTN/GSM net
is OK.
• Relay will be deactivated when power supply is gone more then
15 min or when there is no GSM-net.
Emergency bell
• Relay will be activated when the emergency bell input is active.
• Relay will be deactivated when the emergency bell input is
deactivated.
Relay functions
This applies for SW 4.00 or later.
(For functions of earlier versions,
please contac t the Support team.)
Relays 1 and 2 can be
programmed independently.
Call retry failure
• Relay is activated when current relay is in Standby Mode.
• Relay is deactivated if failing to deliver an alarm. If Fallback is
active, both inter faces have failed. Relay closes at successful
deliverance.
Automatic emergency button check
• Relay is active once every day, checking emergency but ton.
• Relay is deactivated when emergency button input is changed,