- 33 -
calibration mode. The indoor temperature will begin flashing.
Press the CHANNEL/+ key or MAX/MIN/- key to increase or
decrease the temperature reading (in increments of 0.1). Press
and hold the CHANNEL/+ key or MAX/MIN/- key for three
seconds to increase or decrease rapidly.
Press the ALARM key to reset current value.
Press the SET key switch to outdoor temp calibration mode.
To exit the temperature calibration mode at any time, press the
SNOOZE/LIGHT button on the top of the display console. If no
operation is performed, the calibration mode will timeout in 30
seconds.
9.2 Calibration of Humidity Mode
In normal mode, press and hold the SET and MAX/MIN/- keys
at the same time for five seconds to enter into the humidity
calibration mode. The indoor humidity will begin flashing.
Press the CHANNEL/+ key or MAX/MIN/- key to increase or
decrease the humidity reading (in increments of 1%). Press
and hold the CHANNEL/+ key or MAX/MIN/- key for three
seconds to increase or decrease rapidly.
Press the ALARM key to reset current value.
Press the SET key switch to outdoor humidity calibration
mode.