  • E
    Erica MitchellSep 23, 2025
    What to do if Keyboard without display after power on SAJ Controller?
    • A
      Anthony MorseSep 23, 2025
      To solve the keyboard without display after power on problem: * Use a multimeter to measure the input voltage of the controller; check the voltage is normal. * Check if the machine has a burning smell; if there is a burning smell, please contact the agent to replace the controller.
  • G
    gomezkimberlyAug 23, 2025
    Why does my SAJ PDS23-2SR75 Controller show an E001 IGBT module fault?
    • H
      harrisandrewAug 23, 2025
      An IGBT module fault (E001) in your SAJ Controller can occur due to several reasons. It may be caused by: * Too short acceleration time: Increase acceleration time. * Damaged IGBT module: Ask for support. * Malfunction caused by interference: Inspect external equipment and eliminate interference. * Improperly grounding: Check grounding wire.
  • S
    Stephen DavisAug 25, 2025
    What to do if SAJ Controller displays E002 over-current during acceleration?
    • M
      Melanie MillerAug 26, 2025
      If your SAJ Controller shows an E002 error (Over-current during acceleration), it could be due to: * Too fast acceleration: Increase acceleration time. * Too low input voltage: Check the input power supply or wiring. * Lower-rating controller: Replace with higher-rating controller.
  • A
    Abigail ArmstrongAug 27, 2025
    Why does my SAJ Controller show E004 over-current at constant running speed?
    • M
      Mary Hopkins PhDAug 27, 2025
      If your SAJ Controller displays error E004, indicating over-current at constant running speed, there are several potential causes: * Sudden change of load: Check the load. * Too low input voltage: Check the input power supply or wiring. * Lower-rating controller: Replace with higher-rating controller.
  • U
    ugoldenAug 27, 2025
    What causes E003 over-current during deceleration in my SAJ Controller?
    • A
      Andre BlackburnAug 27, 2025
      The E003 error on your SAJ Controller, indicating over-current during deceleration, may be caused by: * Too-fast deceleration: Increase deceleration time. * Too-heavy and large-inertia load: Add proper braking units. * Lower-rating controller: Replace with higher-rating controller.
  • H
    Henry HuffmanSep 18, 2025
    What to do if DC switch trip when power on SAJ PDS23-2SR75 Controller?
    • K
      Katherine AndrewsSep 18, 2025
      To solve the DC switch trip when power on problem: * A multimeter can be used to check the internal circuit of the controller, if there is a short circuit, the machine has been damaged. * Check if the machine has a burning smell; if there is a burning smell, please contact the agent to replace the controller.
  • K
    kleintonySep 15, 2025
    What does E020 well level fault mean on my SAJ PDS23-2SR75 Controller?
    • M
      Michelle LucasSep 15, 2025
      If your SAJ Controller displays the E020 error, indicating a Well Level Fault, it's likely caused by: * Dry well or slow water recovery: Wait for water to recover or reinstall the pump.
  • C
    Caleb NobleSep 16, 2025
    What does E021 tank level fault before auto start mean on my SAJ Controller?
    • V
      Vanessa AndersonSep 16, 2025
      If your SAJ Controller displays error E021, indicating a Tank Level Fault before auto start, it means: * High level limit is reached: Wait until water level comes below the low level limit, and then the PDS23 Solar controller will start the pump again.
  • S
    Shannon KingSep 6, 2025
    What causes the E007 over-voltage at constant running speed error on my SAJ PDS23-2SR75 Controller?
    • J
      Jared GardnerSep 7, 2025
      If you're seeing an E007 error on your SAJ Controller, which indicates over-voltage at constant running speed, it's likely caused by: * Abnormal input voltage: Install proper input AC reactor.
  • R
    Robert HermanSep 3, 2025
    What to do if SAJ Controller displays E010 controller overload?
    • V
      Vicki LopezSep 3, 2025
      If your SAJ Controller is showing an E010 error (Controller overload), it may be due to: * Too fast acceleration: Increase acceleration time. * Avoid prompt restart when trip-off.

Summary

Notes for Safe Operation

Before Installation

Safety warnings and precautions to observe before commencing controller installation.

Installation

Safety cautions and warnings to follow during the controller installation process.

Operation

Safety cautions and guidelines for operating the controller during use.

Maintenance and check

Safety warnings for performing maintenance and checks on the controller and system.

Chapter 3 Mechanical and Electrical Installation

3.2 Electrical Installation

Instructions for wiring terminals, DC power, ground, motor connections, and system wiring diagrams.

Chapter 4 Start-up and Operation

Chapter 5 Diagnostics and Troubleshooting

5.1 Fault Codes

List of fault codes, their descriptions, possible causes, and recommended remedies for troubleshooting.

5.2 Common Faults and Remedies

Troubleshooting common operational issues such as pump failure, over current, and communication errors.

Chapter 7 Backup AC power

SAJ PDS23-2SR75 Specifications

General IconGeneral
Number of DC Inputs2
Rated AC Voltage (V)400
Protection degreeIP65
Power Factor0.8 leading - 0.8 lagging
CommunicationRS485
ProtectionDC reverse polarity
Operating Temperature-25°C to +60°C
Storage Temperature-40°C to +70°C
Humidity0-100% (non-condensing)

Related product manuals