PDS23 Plus Solar Pump
ControllerUser Manual
Version code
PDS23 Plus-EN-60200183-1707

Questions and Answers

  • A
    Anthony ReedSep 9, 2025
    What to do about over-voltage at constant running speed with SAJ Controller?
    • D
      David SmithSep 9, 2025
      If you are experiencing over-voltage at constant running speed with your SAJ Controller, install a proper input AC reactor, as the cause is an abnormal input voltage.
  • D
    destiny40Aug 23, 2025
    Why is my SAJ PDS23 Plus showing a motor overload?
    • S
      Sandra HernandezAug 23, 2025
      A motor overload on your SAJ Controller can occur if the input voltage is too low, so check the input power supply or wiring. Alternatively, the controller may be under-rated for the motor; in this case, consider replacing it with a higher-rated controller.
  • H
    Heather RushAug 25, 2025
    How to fix an overheating SAJ PDS23 Plus?
    • A
      Ana MarshallAug 25, 2025
      If your SAJ Controller is overheating, there are several things you can check. First, refer to the over-current remedy, as an instantaneous over-current could be the cause. Ensure there is no output short circuit by re-wiring the output. Check the cooling fans; replace them if they've stopped or are damaged, and clear any obstructions in the ventilation channel. If the ambient temperature is too high, try to decrease it. Inspect and tighten any loose cables or terminals. If these steps don't resolve the issue, it may be due to an abnormal power circuit.
  • P
    Philip DanielAug 26, 2025
    What to do if there's over-current during acceleration with my SAJ PDS23 Plus Controller?
    • S
      sharonmartinezAug 27, 2025
      If you're experiencing over-current during acceleration with your SAJ Controller, it could be due to a few reasons. The acceleration may be too fast, so try increasing the acceleration time. Also, check the input power supply or wiring, as the input voltage might be too low. If neither of these resolves the issue, the controller might be under-rated, and you should replace it with a higher-rated one.
  • T
    Timothy PayneAug 27, 2025
    Why am I getting over-current at constant running speed on my SAJ Controller?
    • K
      Kim SchultzAug 27, 2025
      If your SAJ Controller is showing over-current at a constant running speed, it could be due to a sudden change of load, so check the load. Another possibility is that the input voltage is too low, so check the input power supply or wiring. It could also be that the controller is under-rated, requiring a replacement with a higher-rated controller.
  • J
    James WallaceAug 29, 2025
    What causes over-current during deceleration in an SAJ PDS23 Plus?
    • M
      marydeanAug 29, 2025
      Over-current during deceleration in your SAJ Controller can be caused by deceleration that is too fast; increase the deceleration time to resolve this. If the load is too heavy and has large inertia, add proper braking units. The controller may also be under-rated, so consider replacing it with a higher-rated controller.
  • C
    Calvin DavisSep 18, 2025
    What should I do if my SAJ PDS23 Plus shows a tank level fault before auto start?
    • C
      Christian ChoiSep 18, 2025
      If your SAJ solar controller displays a tank level fault before auto-start, it means the high-level limit has been reached. Wait until the water level comes below the low-level limit, and then the controller will start the pump again.
  • E
    Edward NelsonSep 22, 2025
    Why does the DC switch trip when I power on my SAJ controller?
    • K
      Kerri WagnerSep 22, 2025
      If the DC switch trips when you power on your SAJ controller, there might be a short circuit. Check the internal circuit of the controller.
  • S
    Susan WilsonSep 8, 2025
    How do I fix a communication fault on my SAJ PDS23 Plus?
    • S
      Scott SmithSep 8, 2025
      To address a communication fault on your SAJ Controller, verify that the baud rate setting is correct. Check communication devices and cables if there is a long-time communication interruption.
  • V
    Victoria OdomSep 4, 2025
    Why am I seeing an under voltage of DC bus error on my SAJ Controller?
    • K
      Kathryn ThomasSep 4, 2025
      If you're encountering an under voltage of DC bus error on your SAJ Controller, it's likely due to an input voltage that is too low. Check the input power supply or wiring to ensure it's within the correct range.

Summary

Notes for Safe Operation

Before Installation

Safety precautions and warnings related to the installation process of the controller.

Installation

Guidelines and precautions for installing the controller on appropriate materials and locations.

Operation

Safety instructions and warnings for operating the controller and pump during use.

Maintenance and Check

Safety warnings for qualified personnel performing maintenance and inspection of the controller.

General Information

Protection Features

Electronic monitoring capabilities for system protection, including dry well, over-voltage, and short circuit.

Mechanical and Electrical Installation

Mechanical Installation

Guidance on overheat protection and selecting the best location for controller installation.

Electrical Installation

Details on terminal blocks, DC wiring, junction box, ground wiring, and motor wiring.

Start-up and Operation

Parameter Setting

Step-by-step process for setting function codes and parameters, illustrated with an example.

Trial Operation

Steps for checking wiring, testing voltage, powering on, setting parameters, and checking motor direction.

Diagnostics and Troubleshooting

Fault Codes

List of fault codes, their descriptions, possible causes, and recommended remedies.

Common Faults and Remedies

Common malfunctions like pump not running, over current, overload, and troubleshooting steps.