8000m Series Compact AC Drive
User Manual
Version Code :8000m-E-602000600-1705

Questions and Answers

  • M
    Marc SimpsonSep 8, 2025
    What to do if SAJ 8000m shows E016 error?
    • K
      kimberlymaldonadoSep 9, 2025
      If your SAJ Controller is showing error E016, it could be due to an improper baud rate setting (set proper baud rate), receiving wrong data (push STOP/RESET to reset and ask for support), or communication being interrupted for a long time (check communication devices and cables).
  • A
    Anthony MckenzieAug 23, 2025
    What should I do if my SAJ Controller displays error E001?
    • E
      Erika VillegasAug 23, 2025
      If your SAJ Controller shows error E001, it might be due to several reasons: the acceleration time being too short (increase acceleration time), a damaged IGBT module (ask for support), malfunction caused by interference (inspect external equipment and eliminate interference), or improper grounding (check grounding wire).
  • C
    Christopher Davis Jr.Aug 25, 2025
    What to do if SAJ Controller shows E002 error?
    • M
      Mr. Jose Green DDSAug 26, 2025
      If the SAJ Controller shows error E002, it could be due to accelerating too fast (increase acceleration time), low input voltage (inspect the input power supply or wiring), or insufficient drive capacity (select a larger capacity drive).
  • S
    Shaun CoxAug 27, 2025
    What to do if SAJ Controller shows E011 error?
    • M
      Michelle MartinAug 27, 2025
      If the SAJ Controller displays error E011, the possible causes include low input voltage (inspect the voltage of the power grid), improper setting of motor rated current (properly set the motor rated current), an improper motor’s overload protection threshold (inspect load and boost the torque), or the drive capacity being too low (select a larger capacity drive).
  • J
    Justin RoyAug 28, 2025
    Why does my SAJ 8000m Controller show E004 error?
    • E
      Erin SimmonsAug 28, 2025
      The E004 error on your SAJ Controller can be triggered by a sudden change of load (check the load), low input voltage (inspect the input power supply or wiring), or insufficient drive capacity (select a larger capacity drive).
  • G
    Gary WalkerSep 23, 2025
    What to do if SAJ Controller shows E022 error?
    • D
      Danielle WilliamsSep 23, 2025
      If your SAJ Controller displays error E022, it could be due to a read/write fault of control parameters (push STOP/RESET to reset and ask for support) or a damaged EEPROM.
  • D
    darryl16Sep 16, 2025
    What to do if SAJ Controller shows E013 error?
    • A
      Amy HornSep 16, 2025
      If your SAJ Controller shows error E013, it could be due to a broken wire in the output cable (check the wiring and installation), a broken wire in the motor winding, or loose output terminals.
  • T
    Teresa TurnerSep 18, 2025
    What to do if SAJ Controller shows E018 error?
    • A
      angela39Sep 18, 2025
      If your SAJ Controller displays error E018, it could be due to loose wires or connectors of the control board (check the wiring and connectors), an amplifying circuit abnormality (ask for support), a damaged Hall sensor, or a power circuit abnormality.
  • R
    robertsonjeffreySep 7, 2025
    What to do if SAJ 8000m Controller shows E007 error?
    • S
      Stacy DavisSep 7, 2025
      If your SAJ Controller displays error E007, it may be due to abnormal input voltage (install input AC reactor) or the load inertia being too large (add suitable braking units).
  • J
    Joshua SinghSep 4, 2025
    What to do if SAJ 8000m shows E005 error?
    • D
      Diana ReeseSep 4, 2025
      If your SAJ Controller displays error E005, it could be due to abnormal input voltage (inspect input power) or restarting the motor too quickly after an instantaneous trip-off (avoid prompt restart when trip-off).

Summary

Safety Instructions

Installation and Wiring Guide

Wiring Connections and Precautions

Detailed wiring diagrams, terminal descriptions, and main/control circuit precautions.

Keypad Operation and Parameter Setting

Function Parameter Reference

Start, Stop, and Motor Control Parameters (F1-F3 Groups)

Covers start/stop modes, braking, motor specs, and vector control.

V;F Control, Input;Output, and Display Parameters (F4-F7 Groups)

Details V/F curves, input/output terminals, display settings, and PID control.

Auxiliary, Protection, Communication, and PLC Parameters (F8-FD Groups)

Covers auxiliary functions, protection, communication, and PLC/multi-step speed.

Troubleshooting Common Issues

Fault Code Diagnosis and Resolution

Lists fault codes, reasons, and specific solutions for VFD errors.

General Faults and Solutions

Addresses common issues like no display, breaker trips, and motor problems.

Communication Protocol (Modbus)

SAJ 8000m Series Specifications

General IconGeneral
BrandSAJ
Model8000m Series
CategoryController
LanguageEnglish