EasyManua.ls Logo

SAJ PDS23-4T011 - User Manual

SAJ PDS23-4T011
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PDS23 Solar Pump Controller
User Manual
Version code
PDS23-EN-602000561-1702

Questions and Answers

  • M
    melindadaltonSep 23, 2025
    What to do if Keyboard without display after power on SAJ PDS23-4T011 Controller?
    • C
      Chad ToddSep 23, 2025
      To solve the keyboard without display after power on problem: * Use a multimeter to measure the input voltage of the controller; check the voltage is normal. * Check if the machine has a burning smell; if there is a burning smell, please contact the agent to replace the controller.
  • K
    kelleyjacobAug 23, 2025
    Why does my SAJ Controller show an E001 IGBT module fault?
    • J
      Jon SmithAug 23, 2025
      An IGBT module fault (E001) in your SAJ Controller can occur due to several reasons. It may be caused by: * Too short acceleration time: Increase acceleration time. * Damaged IGBT module: Ask for support. * Malfunction caused by interference: Inspect external equipment and eliminate interference. * Improperly grounding: Check grounding wire.
  • T
    Thomas HerringAug 25, 2025
    What to do if SAJ Controller displays E002 over-current during acceleration?
    • D
      Deanna HigginsAug 25, 2025
      If your SAJ Controller shows an E002 error (Over-current during acceleration), it could be due to: * Too fast acceleration: Increase acceleration time. * Too low input voltage: Check the input power supply or wiring. * Lower-rating controller: Replace with higher-rating controller.
  • K
    Kevin GarciaAug 27, 2025
    Why does my SAJ PDS23-4T011 show E004 over-current at constant running speed?
    • M
      Mitchell ThomasAug 27, 2025
      If your SAJ Controller displays error E004, indicating over-current at constant running speed, there are several potential causes: * Sudden change of load: Check the load. * Too low input voltage: Check the input power supply or wiring. * Lower-rating controller: Replace with higher-rating controller.
  • R
    robertchristensenAug 27, 2025
    What causes E003 over-current during deceleration in my SAJ PDS23-4T011 Controller?
    • J
      Jill WilliamsAug 27, 2025
      The E003 error on your SAJ Controller, indicating over-current during deceleration, may be caused by: * Too-fast deceleration: Increase deceleration time. * Too-heavy and large-inertia load: Add proper braking units. * Lower-rating controller: Replace with higher-rating controller.
  • A
    Alexander GrahamSep 18, 2025
    What to do if DC switch trip when power on SAJ PDS23-4T011 Controller?
    • K
      kendra28Sep 18, 2025
      To solve the DC switch trip when power on problem: * A multimeter can be used to check the internal circuit of the controller, if there is a short circuit, the machine has been damaged. * Check if the machine has a burning smell; if there is a burning smell, please contact the agent to replace the controller.
  • G
    Gregory RodriguezSep 15, 2025
    What does E020 well level fault mean on my SAJ Controller?
    • L
      Lisa PittsSep 15, 2025
      If your SAJ Controller displays the E020 error, indicating a Well Level Fault, it's likely caused by: * Dry well or slow water recovery: Wait for water to recover or reinstall the pump.
  • N
    nathanmaysSep 16, 2025
    What does E021 tank level fault before auto start mean on my SAJ Controller?
    • R
      Ronald HallSep 17, 2025
      If your SAJ Controller displays error E021, indicating a Tank Level Fault before auto start, it means: * High level limit is reached: Wait until water level comes below the low level limit, and then the PDS23 Solar controller will start the pump again.
  • B
    Brittany SmithSep 6, 2025
    What causes the E007 over-voltage at constant running speed error on my SAJ PDS23-4T011 Controller?
    • S
      Stephen HarrisonSep 6, 2025
      If you're seeing an E007 error on your SAJ Controller, which indicates over-voltage at constant running speed, it's likely caused by: * Abnormal input voltage: Install proper input AC reactor.
  • J
    Julie RamosSep 3, 2025
    What to do if SAJ PDS23-4T011 displays E010 controller overload?
    • S
      Steven LaraSep 4, 2025
      If your SAJ Controller is showing an E010 error (Controller overload), it may be due to: * Too fast acceleration: Increase acceleration time. * Avoid prompt restart when trip-off.

Summary

Preface

Notes for Safe Operation

Essential safety guidelines for installation, operation, and maintenance procedures.

Chapter 2 General Information

2.3 Protection Features

Explains the controller's built-in electronic monitoring and automatic shutdown mechanisms.

Chapter 3 Mechanical and Electrical Installation

Chapter 4 Start-up and Operation

4.3 Trial operation

Outlines the necessary checks and procedures for the initial system startup.

Chapter 5 Diagnostics and Troubleshooting

5.1 Fault Codes

Provides a comprehensive list of fault codes, their causes, and recommended remedies.

5.2 Common Faults and Remedies

Discusses typical operational problems and their practical solutions for the controller.

Chapter 6 Regular maintenance

Chapter 7 Backup AC power

SAJ PDS23-4T011 Specifications

General IconGeneral
BrandSAJ
ModelPDS23-4T011
CategoryController
LanguageEnglish