If there is no enough sun light, and the controller's input power is not enough.
Motor wiring errors cause the pump to reverse, change the wiring.
The motor shaft vibratesand can not rotate, it may be caused by the wiring
errors;Need to re check the motor wiring.
Pumps and pipes are clogged with mud and debris, and the pump can't run
5.2.2 Controller over current, overload faultE002/3/4/10/11
The controller appears over current and overload failure may be due to the following
reasons:
The pump or pipe plug causes the pump current increase and the controller
protection; Need to pull out the pump and check
Because of the increase in operating current of the pump, which is caused by the
pump wire is too long, the controller will be protected, and the controller will be
enlarged to use.
5.2.3 DC switch trip when power on
A multimeter can be used to check the internal circuit of the controller, if there is
a short circuit, the machine has been damaged
Check if the machine has a burning smell; if there is a burning smell, please
contact the agent to replace the controller
5.2.4 The keyboard without display after power on
Use a multimeter to measure the input voltage of the controller; check the
voltage is normal.
Check if the machine has a burning smell; if there is a burning smell, please
contact the agent to replace the controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ PDS23 Plus and is the answer not in the manual?

SAJ PDS23 Plus Specifications

General IconGeneral
BrandSAJ
ModelPDS23 Plus
CategoryController
LanguageEnglish