7.1
Fault
Description
If
fault
happens
during
the
operation
of
the
SKI780
inverter
system,
the
inverter
will
stop
the
output
immediately,
and
the
inverter
fault
relay
will
make
contact
action.
The
inverter
panel displays
the
fault
code,
the
corresponding
fault
types
and
common
solutions
are
shown
in
the
table
below.
List
in
the
form
for
reference
only,
please
do
not
repair
or
modify.
If
unable
to
troubleshoot,
please
seek
technical
support
from
our
company
or
product
agent.
7.2
Troubleshooting
List
Fault
Name
Display
Possible
Causes
Solutions
Inverter
Unit
ErrO1
Protection
1:
The
output
circuit
is
grounded
or
short
circuited.
2:
The
connecting
cable
of
the
motor
Is
too
long.
3:
The
IGBT
overheats.
4:
The
internal
connections
become
loose.
5:
The
main
control
board
ts
faulty.
6:
The
drive
board
is
faulty.
T:
The
AC
drive
IGBT
is
faulty.
1:
Eliminate
external
faults.
2:
Install
a
reactor
or
an
output
filter.
3:
Check
the
air
filter
and
the
cooling
fan.
4.
Connect
all
cables
properly.
5:
Contact
technical
support.