16
P0 Standard Function Parameters
Function
Code
Parameter
Name
Setting Range Default Property
P0-13
Frequency upper limit
o󽗈set
0.00Hz ~ maximum
frequency P0-10
0.00Hz
P0-14 Frequency lower limit
0.00Hz ~ frequency
upper limit P0-12
0.00Hz
P0-15 Carrier frequency 2.0kHz ~ 8.0kHz
Model
dependent
P0-16
Carrier frequency
adjustment with
temperature
0: No
1: Yes
1
P0-17 Acceleration time 1
0.00s ~ 650.00s(P0-19=2)
0.0s ~ 6500.0s(P0-19=1)
0s ~ 65000s(P0-19=0)
Model
dependent
P0-18 Deceleration time 1
0.00s ~ 650.00s(P0-19=2)
0.0s ~ 6500.0s(P0-19=1)
0s ~ 65000s(P0-19=0)
Model
dependent
P0-19
Acceleration/
Deceleration time unit
0: 1s
1: 0.1s
2: 0.01s
1
P0-21
Frequency o󽗈set of
auxiliary frequency
source for X and Y
operation
0.00Hz ~ maximum
frequency P0-10
0.00Hz
P0-22
Frequency reference
resolution
2: 0.01Hz 2
P0-23
Retentive of digital
setting frequency
upon power failure
0: Not retentive
1: Retentive
0
6.1 Brief introduction of function code