26
P4 Input Terminals
Function
Code
Parameter
Name
Setting Range Default Property
P4-34
Setting for AI less
than minimum
input
Unit's digit (Setting for AI1 less
than minimum input)
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less
than minimum input)
0, 1 (same as AI1)
Hundred's digit (Setting for AI3
less than minimum input)
0, 1 (same as AI1)
000 ☆
P4-35 DI1 delay time 0.0s ~ 3600.0s 0.0s ★
P4-36 DI2 delay time 0.0s ~ 3600.0s 0.0s ★
P4-37 DI3 delay time 0.0s ~ 3600.0s 0.0s ★
P4-38
DI valid mode
selection 1
0: High level valid
1: Low level valid
Unit's digit (DI1 valid mode)
Ten's digit (DI2 valid mode)
Hundred's digit (DI3 valid mode)
Thousand's digit (DI4 valid
mode)
Ten thousand's digit (DI5 valid
mode)
00000 ★
P4-39
AI1 input voltage/
current selection
0: Voltage input
1: Current input
0 ★
6.1 Brief introduction of function code