P8 Auxiliary Functions
Function
Code
Parameter
Name
Setting Range Default Property
P8-14
Running mode when set
frequency lower than
frequency lower limit
0: Run at frequency
lower limit
1: Stop
2: Run at zero speed
0 ☆
P8-15 Droop control 0.00Hz ~ 10.00Hz 0.00Hz ☆
P8-16
Accumulative power-on
time threshold
0h ~ 65000h 0h ☆
P8-17
Accumulative running time
threshold
0h ~ 65000h 0h ☆
P8-18 Startup protection 0: No 1: Yes 0 ☆
P8-19
Frequency detection value
(FDT1)
0.00Hz ~ maximum
frequency
50.00Hz ☆
P8-20
Frequency detection
hysteresis (FDT hysteresis 1)
0.0% ~ 100.0%(FDT1
electrical level)
5.0% ☆
P8-21
Detection range of
frequency reached
0.0% ~
100.0%(maximum
frequency)
0.0% ☆
P8-22
Jump frequency during
acceleration/deceleration
0: Disabled
1: Enabled
0 ☆
P8-25
Frequency switchover point
between acceleration time 1
and acceleration time 2
0.00Hz ~ maximum
frequency
0.00Hz ☆
P8-26
Frequency switchover point
between deceleration time
1 and deceleration time 2
0.00Hz ~ maximum
frequency
0.00Hz ☆
P8-27 Terminal JOG preferred 0: Disabled 1: Enabled 0 ☆
6.1 Brief introduction of function code