EasyManua.ls Logo

Sako V780 - Page 42

Sako V780
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
P8 Auxiliary Functions
Function
Code
Parameter
Name
Setting Range Default Property
P8-14
Running mode when set
frequency lower than
frequency lower limit
0: Run at frequency
lower limit
1: Stop
2: Run at zero speed
0
P8-15 Droop control 0.00Hz ~ 10.00Hz 0.00Hz
P8-16
Accumulative power-on
time threshold
0h ~ 65000h 0h
P8-17
Accumulative running time
threshold
0h ~ 65000h 0h
P8-18 Startup protection 0: No 1: Yes 0
P8-19
Frequency detection value
(FDT1)
0.00Hz ~ maximum
frequency
50.00Hz
P8-20
Frequency detection
hysteresis (FDT hysteresis 1)
0.0% ~ 100.0%(FDT1
electrical level)
5.0%
P8-21
Detection range of
frequency reached
0.0% ~
100.0%(maximum
frequency)
0.0%
P8-22
Jump frequency during
acceleration/deceleration
0: Disabled
1: Enabled
0
P8-25
Frequency switchover point
between acceleration time 1
and acceleration time 2
0.00Hz ~ maximum
frequency
0.00Hz
P8-26
Frequency switchover point
between deceleration time
1 and deceleration time 2
0.00Hz ~ maximum
frequency
0.00Hz
P8-27 Terminal JOG preferred 0: Disabled 1: Enabled 0
6.1 Brief introduction of function code

Related product manuals