37
6.1 Brief introduction of function code
P8 Auxiliary Functions
Function
Code
Parameter
Name
Setting Range Default Property
P8-28
Frequency detection value
(FDT2)
0.00Hz ~ maximum
frequency
50.00Hz ☆
P8-29
Frequency detection
hysteresis (FDT hysteresis 2)
0.0% ~ 100.0% (FDT2
electrical level)
5.0% ☆
P8-30
Any frequency reaching
detection value 1
0.00Hz ~ maximum
frequency
50.00Hz ☆
P8-31
Any frequency reaching
detection amplitude 1
0.0% ~ 100.0%
(maximum frequency)
0.0% ☆
P8-32
Any frequency reaching
detection value 2
0.00Hz ~ maximum
frequency
50.00Hz ☆
P8-33
Any frequency reaching
detection amplitude 2
0.0% ~ 100.0%
(maximum frequency)
5.0% ☆
P8-34 Zero current detection level
0.0% ~ 300.0% rated
motor current
5.0% ☆
P8-35
Zero current detection
delay time
0.01s ~ 600.00s 0.10s ☆
P8-36
Output overcurrent
threshold
0.0% (no detection)
0.1%–300.0% (rated
motor current)
200.0% ☆
P8-37
Output overcurrent
detection delay time
0.00s ~ 600.00s 0.00s ☆
P8-38 Any current reaching 1
0.0%–300.0% (rated
motor current)
100.0% ☆
P8-39
Any current reaching 1
amplitude
0.0% ~ 300.0% (rated
motor current)
0.0% ☆
P8-40 Any current reaching 2
0.0% ~ 300.0% (rated
motor current)
100.0% ☆