U0 Monitoring Parameters
Function
Code
Parameter
Name
Setting
Range
Default Property
U0-00 Running frequency (Hz) 0.01Hz
U0-01 Set frequency (Hz) 0.01Hz
U0-02 Bus voltage (V) 0.1V
U0-03 Output voltage (V) 1V
U0-04 Output current (A) 0.01A
U0-05 Output power (kw) 0.1kW
U0-06 Output torque (%) 0.1%
U0-07 DI input state 1
U0-08 DO output state 1
U0-09 AI1 voltage (V) 0.01V
U0-10 AI2 voltage (V)/current (mA) 0.01V/0.01mA
U0-11 Panel potentiometer voltage (V) 0.01V
U0-12 Count value 1
U0-13 Length value 1
U0-14 Load speed display 1
U0-15 PID setting 1
U0-16 PID feedback 1
U0-17 PLC stage 1
U0-18 HDI input pulse frequency (Hz) 0.01kHz
U0-19 Feedback speed (Hz) 0.01Hz
U0-20 Remaining running time 0.1Min
U0-21 AI1 voltage before correction 0.001V
U0-22
AI2 voltage (V)/current (mA) before
correction
0.001V/0.01mA
U0-23
Panel potentiometer voltage before
correction
0.001V
6.1 Brief introduction of function code