Pre-installation Checklist (continued)
Don’ts
Never fit the pump to the cold water mains
Never fit the pump to shared incoming mains supplies to a block of flats
Never use a shared water supply or shared, communal cold water storage cistern
Never put a non-return valve (NRV), restrictive ballofix or an air vent on supply
pipe work to the pump
The hot water supply must not exceed temperature stated in the installation guide
Never use mechanical tools to tighten plastic coupler nuts as this may cause damage
and invalidate your warranty
Never use jointing compounds, Boss White, Hemp or steel wool
Solder fluxes must not come into contact with the pump or AV couplers (hoses)
Never pump directly to or from any pump such as secondary return pump or a shower with
integral pump.
Never fit pump to a Fortic Cylinder, primatic cylinder, Elson Tank or Andrews type water
heater (on rare occasions where a Fortic cylinder has adequate cold water storage, if all
other fitting criteria can be met, this would be acceptable)
If considering fitting pump to a Horizontal (torpedo) water cylinder then please
contact PumpWise on 0191 516 2002
It is not recommended to pump hot water against cold mains water with a positive head
pump