EasyManua.ls Logo

Samson 3241 - 3.4 Technical Data Overview

Samson 3241
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB 8015 EN 3-5
Design and principle of operation
3.4 Technical data
The nameplates on the valve and actuator
provide information on the control valve ver-
sion. See the 'Markings on the device' chap-
ter.
More information is available in Data Sheet
uT8015.
Conformity
The Type3241 Valve bears the CE, UKCA
and EAC marks of conformity.
Temperature range
Depending on the version, the control valve
is designed for a temperature range from
–10 to +220°C. The use of an insulating
section or bellows seal can extend the tem-
perature range from –196 to +450°C de-
pending on the properties of the materials
used.
Leakage class
Depending on the version, the following
leakage class applies:
Seal (12 on
nameplate)
ME, ST ME, ST PT, PK
Pressure balancing
(14 on nameplate)
D/B
Leakage class
(according to
IEC60534-4)
Min. IV Min. IV VI
Noise emissions
SAMSON is unable to make general state-
ments about noise emissions. The noise emis-
sions depend on the valve version, plant fa-
cilities and process medium.
Optional RFID tag
Application range according to the technical
specications and the explosion protection
certicates. These documents are available
on our website at uwww.samsongroup.com
> Products > Electronic nameplate.
Note