EB 8026 EN 7
Safety instructions and measures
Referenced standards and regulations
The control valves comply with the requirements of the European Pressure Equipment Direc-
tive 2014/68/EU. Valves with a CE marking have a declaration of conformity, which in-
cludes information about the applied conformity assessment procedure. This declaration of
conformity is included in the Appendix of these instructions (see section10.2).
According to the ignition risk assessment performed in accordance with EN13463-1:2009,
section 5.2, the non-electrical control valves do not have their own potential ignition source
even in the rare incident of an operating fault. As a result, they do not fall within the scope of
Directive 2014/34/EU.
Î For connection to the equipotential bonding system, observe the requirements specied in
section 6.4 of EN60079-14 (VDE0165 Part 1).
Referenced documentation
The following documents apply in addition to these mounting and operating instructions:
− Mounting and operating instructions for mounted actuator, e.g. uEB8310-X for
Type3271 and Type3277 Actuators
− Mounting and operating instructions for mounted valve accessories (positioner, solenoid
valve etc.)
− uAB0100 for tools, tightening torques, and lubricant
− For oxygen service: Manual uH01