24
Installation Procedure
English
Installation Procedure
Option
item
SEG1 SEG2 SEG3 SEG4 Function
Current
restriction
θɇϩʪ࣑ࠞ
06
00
100%
(Factory
default)
01 95%
02 90%
03 85%
04 80%
05 75%
06 70%
07 65%
08 60%
09 55%
10 50%
1 1 100%
Dedicated
mode for
cooling/
heating
07
00
Cooling / Heating
operation (default)
0 1 Cooling operation only
0 2 Heating operation only
Long-piping
pressure
ʀɇɵθɇϩͱ࣑ࠟ
08
00
Within
98.4 ft (30 m)
(Factory default)
01
98.4 ~ 164.0 ft
(30 ~ 50 m) (Cooling:-
9.96psi, Heating:+4.27psi)
Target low
pressure
calibration
˙ͱθʀͱͱ˝࣑ࠠ
09
00
Initial set pressure for
cooling
(Factory default)
01 -2.84 psi
0 2 -5.69 psi
0 3 -8.53 psi
04 -11.38 psi
0 5 -14.22 psi
06 +2.84 psi
07 +5.69 psi
08 +8.53 psi
09 +11.38 psi
1 0 +14.22 psi
Option
item
SEG1 SEG2 SEG3 SEG4 Function
Target high
pressure
calibration for
˵ʪɇϩ˝࣑ࠡ
10
00
Initial set pressure for
heating
(Factory default)
01 +2.84 psi
02 +5.69 psi
03 +8.53 psi
04 +11.38 psi
0 5 +14.22 psi
06 -2.84 psi
0 7 -5.69 psi
0 8 -8.53 psi
09 -11.38 psi
1 0 -14.22 psi
• ࣑ࠞAЇθθʪϩθʪϑϩθʀϩͱθɇϩʪࡠǮ˵ʪθʪϑϩθʀϩͱͱΧϩͱϑ
set, cooling and heating performance may decrease.
࣑ࠟƊʪϩϩ˵ϑЭɇЇʪи˵ʪϩ˵ʪϑϩɇʪʒΧΧ˝ʪ˝ϩ˵
exceeds 98 ft.
Do NOT use it for performance enhancement purposes.
࣑ࠠƟɇθ˝ʪϩͱиΧθʪϑϑЇθʪ˙ͱθʀͱͱ˝ʀɇɵʪϑʪϩɇθɇ˝ʪ
of 113.79–170.68 psi.
࣑ࠡƟɇθ˝ʪϩ˵˝˵ΧθʪϑϑЇθʪ˙ͱθ˵ʪɇϩ˝ʀɇɵʪϑʪϩɇ
range of 284.47–526.26 psi.
CAUTION
• Edited option will not be saved if you do not end the
option setting as explained in above instruction.
࢘
While you are setting the option, you may press and hold
the K1 button to reset the value to previous setting.
࢘
If you want to restore the setting to factory default,
press and hold the K4 button while you are in the
option setting mode.
– If you press and hold the K4 button, setting will be
restored to factory default but it doesn’t mean that
restored setting is saved. Press and hold the K2
button. When the segments shows that tracking
mode is in progress, setting will be saved.