EasyManua.ls Logo

Samsung AM TNVD Series - Installation Safety Warnings; Power Line and Extension Use; Qualified Installation Requirement

Samsung AM TNVD Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Installation Procedure
English
Installation Procedure
Step 3 Installing the indoor unit
Before fixing the installation plate to the wall or window
frame, you must determine the position of the 65mm hole
through which the cable, pipe and hose pass to connect the
indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected
from the:
Right
Left
Underside (right)
Rear (right or left)
Left Right
Underside
1 Determine the position of the pipe and drain hose hole
as seen in the picture and drill the hole with an inner
diameter of 65mm so that it slants slightly downwards.
a
b c
Plastic anchor
Wall
20 mm
Possible positions for hole
behind unit
Center of indoor unit
Pipe bundle hole: Ø 65 mm (Unit : mm)
Model a b c
**015/022/028/036** 165 305 416
**045/056/071/082** 150 305 650.5
2 If you fix the indoor unit to a wall, fix the installation plate
to the wall giving attention to the weight of the indoor
unit.
Level
Screw Location
x 4ea
NOTE
If you mount the plate to a concrete wall by using
plastic anchors, make sure that gaps between the wall
and the plate, created by projected anchor, are less
than 20 mm.
3 If you fix the indoor unit to a window frame, follow 4 to 6.
4 Determine the positions of the wooden uprights to be
attached to the window frame.
5 Attach the wooden uprights to the window frame giving
attention to the weight of the indoor unit.
6 Attach the installation plate to the wooden uprights using
tapping screw.
Step 4 Purging the unit
Upon delivery, there may be inert gas inside the indoor unit.
Purge the gas from the indoor unit before connecting the
assembly pipe.
Unscrew the caps at the end of each pipe. All inert gas
exhausts from the indoor unit.
NOTE
To prevent dirt or foreign substances from getting into
the pipes during installation, do NOT remove the caps
completely until you are ready to connect the pipes.
DB68-08953A-00_IM_DVM QMD_EU_EN_.indd 6 2020-02-10 오후 4:23:06