3-12
Operating Instructions and Installation
3-2-2(i) Refrigerant Adjustment
3-2-2(j) Flare unt fixing torque
Class
Air-Purge
Method
Refer to the
detailed Air-Purge
Procedure
Refrigerant
Adjustment
Unnecessary
Add 10g of refrigerant
(R-22) for every 1m.
Air-Purge
Method
Purge air using a
vaccum pump
or an additional
refrigerant cylinder.
Refrigerant
Quantity
refer to
specification sheet
Add 10g of refrigerant
(R-22) for every 1m.
Connection
Pipe Length
5m Max.
5~10m
At installation
Outter diameter
160
300
500
200
350
550
6.35 (9000Btu, 12000Btu)
(Liquid Side)
9.52 (9000Btu)
(Gas Side)
12.7 (12000Btu)
(Gas Side)
Torque (kg-cm)
Fixing Torque Final Torque
At service