Connecting the Refrigerant Pipe
There are two refrigerant pipes of different diameters:
A smaller one for the liquid refrigerant
A larger one for the gas refrigerant
The inside of copper tube must be clean & has no dust.
The connection procedure for the refrigerant pipes varies according to
the exit position of the pipes from the indoor unit, as seen when facing
the indoor in the “A” side.
Liquid refrigerant port
Gas refrigerant port
Drain hose port
Remove the pinch pipe on the pipes and connect the assembly pipes to
each pipe, tightening the nuts, first manually and then with a torque
wrench, a spanner applying the following torque.
1
Must use insulator which is thick enough to cover the refrigerant tube to
protect the condensate water on the outside of pipe falling onto the floor
and the efficiency of the unit will be better.
2
Cut off any excess foam insulation.
3
Be sure that there must be no crack or wave on the bended area.
4
It would be necessary to double the insulation thickness(0.4 inch or more)
to prevent condensation even on the insulator when if the installed area is
warm and humid.
5
If the pipes must be shortened refer to page 14.
NN
NN
oo
oo
tt
tt
ee
ee
Outer
Diameter Torque
1/4
inch 10.1~12.3 ft.lb
3/8 inch 18.1~20.3 ft.lb
1/2 inch
27.5~30.4 ft.lb
5/8 inch 31.8~34.7 ft.lb
E-
13
ENGLISH
INSTALLING THE
I
NDOOR UNIT
Gas
refrigerant port
Drain hose port
A
Refrigerant oil
The designs and shape are subject to change
according to the model.
Torque wrench
Flare nut
Union
Spanner
Liquid
refrigerant port