Deciding on Where to Install the Air Conditioner
(Continued)
Piping length and the height
Dimension
Compositio
n
1 Room max
length
82 ft
A,
B, C, D
4 Room total max
length
229.7 ft
A + B + C + D
Max height between
indoor units
24.6 ft
(h)
Max height between
indoor unit & outdoor unit
49.2 ft
(H)
11.8 inch
minimum
23.6 inch
minimum
23.6 inch
minimu
m
11.8 inch
minimum
Main power switch
(h) (H)
A B C D
MH080FXCA4A
1, 208-230, 60
Indoor unit Outdoor unit
Power
supply
Ø,
V, Hz
MH080FXCA4A
026/035/052
✴✴ 026/035✴✴
✴✴ 052✴✴
Liquid
1/4
1/4
Gas
3/8
1/2
Unit
Outside diameter
Piping outside diameter