4.Troubleshooting
â–şErrorCode
A2–1210
A2–2110
â–şErrormessage
Error:#A2-1210/FanFailure:#A2-1210.Turnoffthenon.Callforserviceiftheproblempersists
Error:#A2-2110/FanFailure:#A2-2110.Turnoffthenon.Callforserviceiftheproblempersists
â–şSymptom
MainfanorSMPSfanisnotoperational.
â–şTroubleshootingmethod
NOTE
•SMPSfanerror:A2–1210
•Mainfanerror:A2–2110
1)Turnthemachineoffthenon.
2)Checkifthecorrespondingfanconnectorisconnectedcorrectly.
3)IftheconnectionisOK,EnterSVCmodeandexecutefantest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
4)Ifthefanisnotoperational,measurethefanpower.
a)If24Vpowerisgenerated,replacethedefectivefan.
•SMPSfan:JC31-00152B
•Mainfan:JC31-00161A
b)If24Vpowerisnotgenerated,
•Measurethe24VpowerontheSMPSboard.IftheSMPSboardisdefective,replaceit.
•IftheSMPSboardisnormal,replacethemainboard.
5)Ifthefanoperationisnormalbuttheerrorpersists,
a)Replacethefan.
b)Iftheerrorpersistsafterreplacingthefan,replacethemainboard.
Copyright©1995-2017SAMSUNG.Allrightsreserved.4-39