Samsung ProXpress SL-M4030ND - Error: #A3-3311; Sensor Failure: #A3-3311. Turn off then On. Call for Service if the Problem Persists; Error: #A3-3312; Sensor Failure: #A3-3312. Turn off then On. Call for Service if the Problem Persists; Not Proper Room Temp; the Room Temperature Is Not Suitable for this Set Use. Please Adjust Room Temperature

Samsung ProXpress SL-M4030ND
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
â–şErrorCode
A3–3311
A3–3312
A3–3320
â–şErrormessage
Error:#A3-3311/SensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists
Error:#A3-3312/SensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists
NotproperRoomTemp/Theroomtemperatureisnotsuitableforthissetuse.Pleaseadjustroomtemperature
â–şSymptom
Outertemperaturesensorisdefective.
â–şTroubleshootingmethod
1)Turnthemachineoffthenon.
2)Checkifthemachineisinstalledinproperenvironment.
3)Checktheharnessconnectionbetweenmainboardandtemperaturesensor.Reconnectthesensorharness.
4)Iftheproblempersists,replacethemainboard.
4-40Copyright©1995-2017SAMSUNG.Allrightsreserved.