EasyManua.ls Logo

Samsung RF4287HARS/XAA - Page 69

Samsung RF4287HARS/XAA
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
TROUBLESHOOTING
2) If R Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN30 and CN76 inserted
correctly?
Is R Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#6(White) and
REG1 HEAT-SINK normal?
Is the input voltage of
IC01 MICOM #76 normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wire connection part
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder.
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to
Sensor **
R : CN30#6 CN76#1 measuring resistance value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage IC01 MICOM #76,
CN30#6(White) and REG1, HEAT SINK
from PCB typical Ground part are similar.
Check the measure on the Resistance, R311 due
to the SMD MICOM
Checking method of R Sensor resistance
CN30#6(White) CN76#1(Gray) Compare the
temperature table after measurment.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
R
Connector CN30#6(White) to
REG1 HEAT-SINK PCB typical Ground
Checking method of R Sensor resistance
- Measure the voltage of Sensor Check Point #3(IC01 MICOM
#76) on PCB or CN30#6(White) REG1, HEAT SINK
- Compare the temperature table after measurement.
Measuring voltage of CN30#6(White) REG1, HEAT SINK
are as below.
Typical PCB Ground
REG1, HEAT SINK
AW3 SM-EN 2011.3.31 2:56 PM 7 0 i n