EasyManua.ls Logo

Samsung RF4287HARS/XAA - If FAN Does Not Operate(Flex Room - FAN)

Samsung RF4287HARS/XAA
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
TROUBLESHOOTING
- This refrigerator has BLDC FAN motor. BLDC motor is driven by DC10~12V
- When COMP ON, normally with F-FAN motor.
4-2-4. If FAN does not operate(Flex Room - FAN)
Start
Execute manual operation
No
Yes
Yes
No
Yes
Yes
No
No
Is COMPRESSOR ON ?
Is the Flex
Room temperature suitable for
the Fan working?
Predicted Cause
FAN-MOTOR troubles itself
Bad wiring connections.
Wrong Input of the fan motor rotation pulse
Is the voltage between
CN79-"1"(Orange) and "3"(Blue)
(Black) around DC10~12V?
Does DC7~12V alternate
with below DC2V between CN79-
"1"(Orange) and "3"(Blue)
FAN works normally
Operation
temperature/ready
Replace MAIN PCB
Flex Room control temperature
Sort
Micom
(IC01)
Initial
power On
Heater
off
Working
heater
37
(3)
42
(6)
27
(-3)
32
(0℃)
Temperaure
Checking method of Flex Zoon FAN Motor Voltage with the voltage
between CN79-"1"(Orange) and "3"(Blue) shall be less than DC10~12V
- Additional check if resistance values are different after measurement.
1) Flex Room - FAN
AW3 SM-EN 2011.3.31 2:56 PM 8 2 i n

Table of Contents