Step 1
Disassemble backside UNIT COVER.
Step 2
After disassemble ASSY Valve and check
WHITE 2-Wire
- Normal parts : 350~450
- Failure parts : Open or 0 Ω
Disassemble Main PBA cover which is in the
backside
Inspect Connector which is on the right
bottom
- Inspect CN70 No.3(RED)and CN73
No.1(W/BLK)
Inspect disassembled Unit
Cover 2-Wire
CN 73 No.1(W/BLK) +
CN70 No.3(RED)
Check Point
Inspect WATER VALVE failure
Tip 3-2. Inspect WATER VALVE operation
CN 73
CN 70