76_ functional description
functional description
English English _ 77
FUNCTIONAL DESCRIPTION
Alarm Output
Main Menu/Alarm Setting/Alarm Output
Setting 1,2 :
Enables selecting an Alarm Output method.
1, 2, Motion, and Support Device indicate
alarm input ports, Motion Detection, and
support device input. A total of 4 alarms,
Motion Detection, and support devices can
be set up to output alarms. 1 alarm output
port can be used for more than 2 alarm
inputs and Motion Detection.
Timer 1,2 :
Enables selecting an Alarm Output method.
On : Retains an alarm output for a set
duration from a minimum of 1 second
to a maximum of 60 minutes upon the
alarm occurrence.
Momentary : Retains an alarm output only
until the alarm is canceled.
The Alarm Output is equipped with a relay
circuit. The operation of the alarm output port
is as shown in the diagram below.
Connecting the power connector and GND incorrectly to the NC/NO and COM ports
may cause a short circuit and fi re, damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the
camera’s lifespan and damage it.
►
•
-
•
-
-
❋
M
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
MD Dwell Time OFF
Alarm Output
Setting 1
þ
1
þ
2
þ
MD
þ
AUX
Setting 2
þ
1
þ
2
þ
MD
þ
AUX
Timer 1 OFF
Timer 2 OFF
OUT Off 1
OUT Off 2
NO
COM
NC
Alarm Out OFF
NO
COM
NC
Alarm Out ON
AUX Output menu is to operate the camera’s peripheral devices such as lamps
and sirens through the controller and switches as well as through network
communications.
OUT Off 1,2 :
When an alarm event occurs, the output force can be terminated.
Connecting the power connector and GND incorrectly to the Aux terminal’s NO and
COM ports may cause a short circuit and fi re, damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the
camera’s lifespan and damage it.
•
-
M
NO
COM
AUX On
NO
COM
AUX Off