78_ functional description
functional description
English English _ 79
FUNCTIONAL DESCRIPTION
INITIALIZE
Initialization Menu
Main Menu/Initialize
Power On Reset :
Restarts the camera.
Factory Default Set :
Enables resetting the camera to its factory default
settings. When the mode is selected, all custom
data such as preset locations is deleted from the
camera.
Use this function if it is necessary to reset the
settings of the camera.
Camera Default Set :
Resets the camera zoom module to the Factory
Default mode; use if you want to reset all camera
settings including Exposure and Backlight.
Auto Refresh :
Enables optimizing the status of the camera’s
built-in electric circuits and components on a
regular basis. (A regular operation can be
scheduled.)
This mode can be used to maintain and repair the current settings of the camera
when anomalous operations occur: e.g. The camera happened to directly face a light
source, or the settings have been canceled after the camera repeatedly rotated in all
four directions for a long time to monitor a specifi c location.
The default setting is Off.
OFF
, 1~7 Days : Selecting Off disables Auto Refresh and selecting 1~7 Days
automatically executes it after 1~7 days has passed.
Auto Refresh takes approximately 10 seconds to fi nish. If Auto Refresh activates in
the middle of a sequence action, the camera pauses the sequence action and
performs an Auto Refresh, then resumes the sequence action once the refresh is
complete.
►
•
•
•
•
-
❋
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Initialize
Power On Reset
Factory Default Set
Camera Default Set
Auto Refresh OFF
PASSWORD SETTING
Password Setting
Main Menu/Password Setting
The Password feature enables you to confi gure a
password for rebooting the camera and accessing
the OSD and preventing unauthorized modifi cation
of existing camera settings.
On/Off :
Enables or disables Password protection.
Edit Password :
Change the password; enter the current
password and then a new one, consisting of 4
hexadecimal characters (0~F).
* The default password is "0000".
In case you have forgotten the current password, use the controller and perform Preset
255 to access the OSD without the password.
Upon using "Factory Default Set" at "Main Menu > Initialize," the password is reset to
the default, "0000".
►
•
•
-
M
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Password Setting
On/Off OFF
Edit Password
Edit Password
Old Pwd : 0 * * *
New Pwd : * * * *