Outdoor Unit
t "WPJEUIFGPMMPXJOHQMBDFTUPQSFWFOUNBMGVODUJPOPGUIFVOJU
- Where there is machine oil - Salty environment such as seaside areas
- Where sulde gas exists - Other special atmosphere areas
4.9inch(125mm)
or more
3.9inch(100mm) or more
4.9inch(125mm)
or more
'L' meters maximum total pipe
length
Wrap the refrigerant
pipes and the
drain hose with the
absorbent pad and
vinyl tape. Refer to page
53 for further details.
You can select the direction of
draining (left or right).
'H' meters
maximum
total pipe
height
K
The appearance of the unit may be dierent from the diagram depending on the model.
One round loop will help reduce noise and vibration.
'L' m as maximum pipe length
and 9.84ft(3m) as minimum pipe
length. (It will reduce noise and
vibration)
Model L H
77
09/12
77
49.2ft(15m) 26.24ft(8m)
77
18/24
77
98.4ft(30m) 49.2ft(15m)
X
Where it is not exposed to strong wind
X
Well ventilated and dustless places
X
Where possible keep out of sunlight and rain
X
Where neighbors are not annoyed by operation sound or hot air
X
Solid wall or support that prevents vibration and is strong enough to hold the product weight
X
Where there is no risk of ammable gas leakage
X
When installing the unit at a high elevation be sure to x the unit legs
X
10' (3m) or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
X
Install the unit horizontally
X
Place where drained water does not become any problem.
X
Place with no plants (especially climbing plants) and where small animal can not access.
X
Outdoor unit should not be place higher than 8'(2.4m) or directly under eaves for accessibility for service and OH&S reasons.
Outdoor
Unit
Indoor
Unit
Outer wall
Cut insulation to
have rainwater
drained
Make an U-trap(A) on the
pipe (which is connected
to the indoor unit) at outer
wall and cut the bottom
part of the insulation (about
10mm) to prevent rainwater
from getting inside through
the insulation. However,
be careful not to damage
the pipe.
A
English-35
INSTALLATION07