Drain hose
Extension
drain hose
Drain hose
Extension
drain hose
1.57~1.77 inch
(
40~45 mm)
Foam Insulation
0.79inch
(20mm)
or more
0.79inch
(20mm)
or more
Vinyl Tape
Changing drain connection
t 5IFIPTFXJMMCFöYFEQFSNBOFOUMZJOUPQPTJUJPOBGUFSöOJTIJOHUIFJOTUBMMBUJPOBOEUIFHBTMFBLUFTU
refer to page 53 for further details.
t .BLFTVSFUIFJOTUBMMFEEJSFDUJPOPGUIFESBJOIPTFJTDPSSFDU
Inadequate installation may cause condensate water leakage.
t *GUIFESBJOIPTFJTSPVUFEJOTJEFUIFSPPNJOTVMBUFUIFIPTFTPUIBUESJQQJOHDPOEFOTBUJPOEPFTOPUEBNBHFUIF
furniture or oors.
t %0/058"--615)&%3"*/)04&$0//&$5*0/
Drain hose connection must be easy accessible and serviceable.
t .BLFTVSFUIFJOEPPSVOJUJTJOVQSJHIUQPTJUJPOXIFOZPVQPVSXBUFSUPDIFDLGPSMFBLBHF
Make sure that the water does not overow onto the electrical part.
Pour the water in direction of arrow.
KDirection of condensate ow
6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
7. Pass the drain hose through the hole in the wall. Check if it slants
downwards as seen in the picture.
8. Using natural drainage method, check the drainage is normal.
Shield
Drain hose Extension drain hose
Change the direction only when it is necessary.
1. Detach the rubber cap with the pliers.
2. Detach the drain hose by pulling it and turning to the right.
3. Insert the drain hose by xing it with the screw into the groove of the drain
hose and the outlet of the drain pan.
4. Attach the rubber cap with a screwdriver by turning it to the left until it
xes to the end of the groove.
5. Check for leakage on both side of the drain outlet.
Rubber cap
Drain pan outlet
Drain hose
Screw hole
Screw
Installing and connecting the condensate drain hose to indoor unit