SPECIFICATIONS
SpinPoint P80 Product Manual Rev. 01 9
3.5 Power Requirements
Table 3-5 Power Requirements
Typical Current (mA rms)
Mode
+5 Volts
+12 Volts
Typical Power
(Watts)
Spin-up(1/2 Disk) 600/600 1900/1900 N/A
Normal 600/600 300/400 6.6/7.8
Idle 480/480 300/400 6.0/7.2
Random Seek
(1)
- - 7.8/9.0
Read/Write
(2)
- -
6.8/8.0
Standby - -
0.3/0.3
Sleep - - 0.3/0.3
1) Random seek: 30% Duty cycle seek commands with logical random location.
2) Read/Write @ OD: On track Read/Write operation at OD, 256 sector commands.