EasyManua.ls Logo

Samsung SyncMaster UD55A

Samsung SyncMaster UD55A
155 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ack
Header
command
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘A’ 0x11 Power
Power : Same as above
Nak
Header command
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘N’ 0x11 ERR
ERR : Error code that shows what occurred error is
Volume Control
Function
Personal Computer changes volume of TV / Monitor.
Get Volume Status
Header
command
ID
DATA Length
CheckSum
0xAA 0x12 0
Set Volume
Header command
ID
DATA
Length
DATA
CheckSum
0xAA 0x12 1 Volume
Volume : Volume value code to be set on TV / Monitor (0 ~ 100)
Ack
Header command
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘A’ 0x12 Volume
Volume : Same as above
Nak
Header
command
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘N’ 0x12 ERR
ERR : Error code that shows what occurred error is