Troubleshooting _ 23
Error Type For USA Causes Remarks
Water Leakage
Error
LC
- Heaterengagementfault.(outofplace)
- Theairhoseisoutofplaceandwaterleakageoccursduring
thespincycle.
- Thetubbackatthesafetyboltsxingpartisbroken.
- Waterleakageoccursatthefrontwithfoamingbecauseoftoo
muchdetergent.
- Waterleakageoccursbecausetheconnectinghosetothe
detergentdrawerisconnectedincorrectly.
- Thedrainpumpltercoverisengagedincorrectly.
- Waterleakageoccursatthedrainhose.
- Theductcondensingholdingscrewsareworn.
- Thenozzle-diaphragmisengagedintheoppositedirectionor
therubberpackagingisomitted.
- Waterleakageoccursbecausethescrewsthatholdthetub
backandfrontinplacearefastenedincorrectly.
- Theleakagesensorisfaulty.
OverowError OC
- Waterissuppliedcontinuallybecausethewaterleveldetection
doesnotwork.
- Becausethedrainhoseiscloggedandthereisaninjection
error(atanarrowsection),thewaterleveldetectiondoesnot
workandwaterissuppliedcontinually.
- Waterissuppliedcontinuallybecauseoffreezingorbecause
thereisforeignmaterialinthewatersupplyvalve.
- Thiserrormayoccurwhenthewaterlevelsensorisdegraded.
Thiserroroccurs
becausethewater
levelsensorterminalis
outofplace.
Temperature
Sensor Error
TC1
- Thewashingheatersensorinthetubhasanerror.
(Contacterrorortemperaturesensorfault)
- Theconnectorisconnectedincorrectlyorisdisconnected.
- Ifthewaterlevelsensoroperateswithoutwaterbecausethe
waterisfrozenorforanyotherreasonandthetemperature
sensorengagedatthebottomtopreventoverheatingforthe
washingheaterdetectsatemperatureof100to150˚C,the
washingmachineturnstheinputpowero.
Heatersensorfault
:Whentheconnector
isconnected
incorrectlyorhasa
wiredisconnectedor
contact error
Unbalance Error UB
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitasdirectedin
theusermanual.
Foaming
Detected
SUD
- Thisoccurswhentoomuchfoamingisdetected.Itisalso
displayedwhilefoamingisremoved.Whentheremovalis
nished,thenormalcycleproceeds.
“Sud”or“SUdS”isdisplayedwhentoomuchfoamingis
detectedand“End”isdisplayedwhentheremovalofthe
foamingisnished.
(Thisisoneofthenormaloperations.Itisanerrorfor
preventingnon-sensingfaults.)
Mems PBA Error
Detected
8C1
- ErrordetectedintheMemsPBAordataerrordetected.
Checkthewireconnections.
Replaceifnecessary.
1.Checkthewireconnections.
2.ReplacetheMemsPBA.
8C2
8C
System Error SF
- MicroControllerOperationFail. ReplaceAssyPCB.