EasyManua.ls Logo

Samsung WF45N5300AF/US - Test Modes

Samsung WF45N5300AF/US
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 _ Troubleshooting
4-2. TEST MODES
No Mode How to enter
1 Smart Install
Standby Smart Install
Set the scheduled
time to 17:00
Press Start/Pause
for 7 seconds
2
Automatic
check mode
Smart Install
Press Start/pause While displaying “AS”.
3
Manual check
mode
Enter Smart Install
Press Delay End While displaying “AS” delay end,
Check devices in turn when pressing delay end.
4
S/W version
Check
Enter Smart Install
Press the rst button on the left at the bottom
While displaying “AS”.
5
Diagnostic Code
Check
Press the rst button on the right at the bottom while
displaying AS”, “Cr. Tum jog dial along the direction for
CW when displaying.
For models that do not feature the jog dial, press the 3rd button
from the bottom left to display the information codes
one by one by one with the latest rst.
Enter Smart Install
Automatic Mode of Smart Install
Automatically start all operation modes of Smart Install.
Manual Mode of Smart Install
Under the condition of manual mode, every time when “Delay End” is pressed, next step will be entered.
Contents like washings, etc. are not allowed in the drum.
1 carry out test for machine door locking 7
carry out test for operation of drainage pump
2
carry out test for drainage pump
operation
8
carry out test for operation of dehydration
3
carry out test for operation of
preparatory valve
9
carry out test for operation of drying heater and
drying fan
Co carry out test for operation of cold water valve 10
carry out test for operation of machine door
Ho carry out test for operation of hot water valve
OK(Ot)
Automatic mode of Smart Install is completed
normally
6
carry out test for operation of water shot valve
carry out test for operation of washing heater
carry out test for operation of rinsing
Accessories not included in the product are not require to check and they can be skipped directly.
Identity of Smart Install completion
After Smart Install is completed normally, OK(Ot) identity will display.
If Smart Install is completed abnormally or Smart Install fails to work, nGidentity will display.
Result Enquiry of Automatic Mode of Smart Install
Under the condition of appearance ofAS identity, press “Delay End + Start/Pause” button.
If automatic mode result is in normal condition, OK(Ot) identity will display.
If automatic checking mode fails to complete normally or fails to execute, nG identity will appear.
Diagnosis Information Display Mode
Under the condition of appearance of AS identity, if the rst button on the right at the bottom is pressed, CR
identity will appear and diagnosis information display mode is entered.
Under the condition of appearance of CR identity, of turn the jog dial control switch clockwise, diagnosis codes gen-
erated before will display 7 digits at most.