This command is reading D-register, which was resisted by STD Command at the TEMI 300
3.9 CLD Command
■ Transmission Format
■ Response
- Parameter number : 1 ~ 32
- dddd : Indicates a character string in hexadecimal format
Ex) When the reading the D-Register that regist on STD Command
- Transmission : [stx]01CLD[cr][lf]
- Transmission (Include Check Sum) : [stx]01CLD34[cr][lf]
Byte
Command
element
1 2 3 1 2 1 4 1 1 . . .
S
T
X
Addr CLD , OK , dddd-1 , , . . .
4
dddd-2
1 4 1 2 1
, dddd-(n-1) , SUM
C
R
4
dddd-(n)
1
L
F
Byte
Command
element
1 2 3
S
T
X
Addr CLD
2 1
SUM
C
R
1
L
F