4. Maintenance
1. To ensure good heat dissipating, please open the lid to clean the dirt after the cooler used in
long-term.
2. Working in cold north area, it is better to use noncorrosive antifreeze fluid.
<4> SPECIFICATIONS
Model
CW-3000TG
CW-3000DG
CW-3000TK
CW-3000DK
Voltage
AC 1P 220V
AC 1P 110V
AC 1P 220V
AC 1P 110V
Frequency
50/60Hz
Current
0.45A
0.9A
0.5A
1.0A
Machine power
0.10KW
0.11KW
Radiating capacity
50W/
Max. lift
10M
70M
Max. flow
10L/min
2L/min
N.W
9.5Kgs
12Kgs
G.W
12Kgs
14.5Kgs
Protection
Flow alarm
Tank capacity
9L
Inlet and outlet
External Φ10mm brass connector
Φ8mm speedy connector
Dimension
49 X 27 X 38cm (L X W X H)
Packing dimension
59 X 39 X 48cm (L X W X H)