pb025nmdl3sm-rev0913 Page 2
* Designates Glass Filled
** Note: Only Conductive Acetal equipped pumps with no options are ATEX compliant
Horizontal suction and vertical discharge are standard. All combinations of suction and discharge are available.
Meanings of Abbreviations:
ATEX Compliant ONLY with no options.
Explanation of Pump Nomenclature
PB¼
Outer
Diaphragm
Plate
Inner
Diaphragm
Plate
Intermediate
Housing
Hardware
Valve
Seat
Diaphragm
Ball Valve
Material
Shipping
Weight
(lbs.)
Manifold
Outer
Chamber
Diaphragm
Rod
Air
Valve
Cap
Options
PP PP 2011-AL PP* 416SS 301/302SS PP S S
TU3PP. PP 2011-AL PP* 416SS 301/302SS PP S T 4
TT3PP. PP 2011-AL PP* 416SS 301/302SS PP T T 4
TS3K. K
PP
2011-AL PP* 416SS 301/302SS K S S 5
TU3K. K
PP
2011-AL PP* 416SS 301/302SS K S T 5
TT3K. K
K
2011-AL PP* 416SS 301/302SS K T T 5
TS3CA. CA
K
2011-AL CA* 301/302SS AC S S 4
TU3CA. CA
K
2011-AL CA* 416SS 301/302SS AC S T 4
TT3CA. CA
CA
2011-AL CA* 416SS 301/302SS AC T T 4
CA
CA
4TS3PP.
416SS
TS3PPE0.
TS3PPE1.
TS3PPE2.
TS3PPE3
TS3PPE4.
TS3PPE8.
TS3PPE5.
TS3PPE9.
TS3PPE6.
TS3PPP0.
TS3PPE7.
TS3PPP2.
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
2011-AL
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
416SS
416SS
416SS
416SS
416SS
416SS
416SS
416SS
416SS
416SS
416SS
416SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
301/302SS
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
4
4
4
4
4
4
4
4
4
4
4
4
PP
PP
PP
K
K
K
CA
CA
CA
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP*
PP*
PP*
PP*
PP*
PP*
CA*
CA*
CA*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
PP*
-
-
-
-
PP*
-
PP*
-
CA*
-
CA*
-
CA*
-
E
PP
E7
P2
E
PP
E6
P0
E5
E9
E
E
E
E
E4
E8
E E3
E E2
E E1
E E0
AC = Acetal
AL = Aluminum
CA = Conductive Acetal**
K = PVDF
PP = Polypropylene
SS = Stainless Steel
T = PTFE
S = Santoprene
R = Hytrel
Kit Options
00.= None
P0.= 10-30VDC Pulse Output Kit
P2.= 110/120 or 220/240VAC
Pulse Output Kit
E0.= Solenoid Kit w/24VDC Coil
E1.= Solenoid Kit w/24VDC
Explosion-Proof Coil
E2.= Solenoid Kit w/24VAC/12VDC Coil
E3.= Solenoid Kit w/12VDC Coil
Explosion-Proof
E4.= Solenoid Kit w/110VAC Coil
E5.= Solenoid Kit w/110VAC
Explosion-Proof Coil
E6.= Solenoid Kit w/220VAC Coil
E7.= Solenoid Kit w/220VAC
Explosion-Proof Coil
E8.= Solenoid Kit with 110VAC, 50 Hz
Explosion-Proof Coil
E9.= Solenoid Kit with 230VAC, 50 Hz
Explosion-Proof Coil
SP.= Stroke Indicator Pins
MATERIALS OF CONSTRUCTION
To order a pump or replacement parts, rst enter the Model Number PB1/4, followed by the Type Designation listed below in the far left column.
Conductive Acetal Models equipped with Integral Mufers:
II 2 G c T5
II 3/2 G c T5
II 2 D c T100 C
I M2 c
Conductive Acetal Models equipped with a metal mufer:
II 1 G c T5
II 3/1 G c T5
II 1 D c T100 C
I M1 c
Ambient temperature range -20 C to +40 C
Process temperature range -20 C to +80 C for models rated as category 1 equipment
-20 c to +100 C for model rated as category 2 equipment
In addition, the ambient temperature range and the process temperature range do not exceed the operating temperature range of the applied non-metallic parts as listed in the manuals of the pumps.