A2 Automatic Dispenser V3.0 15
Issue Code
Cause
Solution
E11
Emergency stop switch is unreleased.
Release it.
E12
Top cover is not closed.
Top cover sensitive switch is broken.
Close it.
Change it.
E18
Base paint can is not located.
The base paint can is too far away from the
sensor.
Base paint can sensor is broken.
Locate it.
Make them nearer.
Adjust it or change it.
E31
Valve motor is broken.
Valve motor driver is broken.
Right valve sensor is too far away.
Right valve sensor is broken.
Change it.
Change the driver circuit board.
Make it nearer.
Change it.
E32
Step motor is broken.
Step motor driver is broken.
Lifting block sensor is too far away.
Lifting block sensor is broken.
Change it.
Change it.
Make it nearer.
Change it.
E35
Rotary plate motor is broken.
Rotary plate motor driver is broken.
Can coder sensor in trouble.
Change it.
Change the driver circuit board.
Change it.
E36
Magnet is not in the proper location.
Can coder is broken.
Locate it properly.
Change it.
E38
Pump is lifted.
Pump sensitive switch is broken.
Reset it.
Change it.
E39
The plate is rotated when the step motor or
valve is not reset.
Check the valve and the sensor.
E41
Valve motor is broken.
Valve motor sensor is broken.
Left valve sensor is too far away.
Left valve sensor is broken.
Change it.
Change the driver circuit board.
Make it nearer.
Change it.