A2 Automatic Dispenser V3.0 15
Emergency stop switch is unreleased.
Top cover sensitive switch is broken.
Base paint can is not located.
The base paint can is too far away from the
sensor.
Base paint can sensor is broken.
Make them nearer.
Adjust it or change it.
Valve motor driver is broken.
Right valve sensor is too far away.
Right valve sensor is broken.
Change the driver circuit board.
Make it nearer.
Change it.
Step motor driver is broken.
Lifting block sensor is too far away.
Lifting block sensor is broken.
Change it.
Make it nearer.
Change it.
Rotary plate motor is broken.
Rotary plate motor driver is broken.
Can coder sensor in trouble.
Change the driver circuit board.
Change it.
Magnet is not in the proper location.
Pump sensitive switch is broken.
The plate is rotated when the step motor or
valve is not reset.
Check the valve and the sensor.
Valve motor sensor is broken.
Left valve sensor is too far away.
Left valve sensor is broken.
Change the driver circuit board.
Make it nearer.
Change it.
Contact the supplier with the model and serial number for other issue(s)