7. Troubleshooting
Symptom
Cause
Action
The motor does not work.
No power
Check if plug and wire are fine;
Check if socket has power.
The fuse is broken.
Replace fuse.
The motor is disconnected.
Open motor case and reconnect
the motor correctly.
The motor is broken.
Replace it.
Uneven flow of colorant
from the nozzle during
dispensing.
Air bubbles in the cylinder
See "Preparation Before
Operation ". Allow the bubbles
to escape
Colorant in canister is low.
Top off colorant.
Dried deposits of colorant causing
blocks.
Clean canister assembly and
relevant parts.
Canister is loose on
turntable.
Loose fastening screws.
Tighten fastening screws.
Colorant doesn’t dispense
easily.
Nozzle blocked.
Clean nozzle.
Piston doesn’t move easily.
Colorant has dried and hardened in
the cylinder.
Canister and pump should be
removed, emptied and cleaned
thoroughly. Replenish with new
colorant.
Agitator doesn’t move during
mixing.
The crank shaft under the canister is
not attached to the plastic sleeve of
the rotating panel.
Reinstall the canister.
Colorant leakage at the
nozzle.
Worn out O-ring.
Replace O-ring.