M3 Manual Dispenser V1.0 6
DLift the handle and make it contact with the gauge head. Hold on for several seconds to make sure
the cylinder is full of colorant.
Notice: do not open or operate the valve key when lift the handle. Or the air would be sniffed into the
cylinder and cause inaccuracy.
EShown as Figure 7: rotate the valve key for 90°and press the handle slowly to its bottom. Release
the valve key and make it back to the original position.
F. Press down the black button, reset the black gauge to its zero position. Release the red button.
(Figure 6)
Black
Gauge
Handle
Red Gauge
Black Button
Red Button
(Figure 7)
Nozzle
End Plate
Valve Key