PRE-PLUMBED UNVENTED MAINS PRESSURE WATER HEATER
120, 150, 170, 210, 250 and 300 LITRE CAPACITY INDIRECT MODELS
INSTALLATION AND SERVICING INSTRUCTIONS
IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS
BEFORE COMMENCING INSTALLATION. PLEASE LEAVE THIS MANUAL
WITH THE CUSTOMER FOR FUTURE REFERENCE.

Questions and Answers

  • D
    donaldvazquezAug 1, 2025
    What to do if Santon Premier Plus 120 Water Heater discharges from T&P Relief Valve?
    • J
      James MoranAug 1, 2025
      If your Santon Water Heater is discharging from the T&P Relief Valve, it could be due to thermal control failure, and the water will be very hot. Switch off power to immersion heater(s) and/or shut down the boiler. Do not turn off the water supply. After the discharge stops, check all thermal controls, and replace them if faulty.
  • S
    Samantha WilliamsAug 13, 2025
    What to do if Santon Water Heater discharges from Expansion Valve?
    • K
      Katherine HuntAug 13, 2025
      If your Santon Water Heater is discharging from the Expansion Valve, it could be due to: * INTERMITTENTLY: The expansion vessel charge pressure has reduced below 3.5 bar. See the Maintenance section for the re-charging procedure. * CONTINUALLY: This could be due to a cold water combination valve pressure reducer not working correctly or an expansion valve seat damaged. * Check the pressure from the cold water combination valve. If it's greater than 3.6 bar, replace the pressure reducer cartridge. * Remove the expansion valve cartridge and check the condition of the seat. If necessary, fit a new expansion valve cartridge.
  • J
    James VasquezAug 19, 2025
    How to fix no hot water flow in Santon Premier Plus 120?
    • M
      marie42Aug 19, 2025
      If there is no hot water flow from your Santon Water Heater, the possible causes and solutions are: * Mains supply off: Check and open the stock cock. * Strainer blocked: Turn off the water supply, remove the strainer, and clean it. * Cold water combination valve incorrectly fitted: Check and refit as required.
  • M
    Ms. Julie LesterAug 25, 2025
    Why is my Santon Premier Plus 120 water milky?
    • T
      Tracey Jacobson DDSAug 26, 2025
      If the water from your Santon Water Heater appears milky, it is likely due to oxygenated water. Water from a pressurized system releases oxygen bubbles when flowing, causing the milkiness. This will disappear after a short while.
  • N
    Nathan OwensNov 6, 2025
    Why is water from hot taps cold in my Santon Water Heater?
    • P
      Philip SimmonsNov 6, 2025
      If the water from your hot taps is cold, several issues could be the cause: * The BACK UP immersion heater might not be switched on. Check and switch it on. * The BACK UP immersion heater thermal cut-out may have operated. Check and reset it by pushing the button. * For INDIRECT systems, the programmer might be set to Central Heating only. Check and set it to the Domestic Hot Water program. * For INDIRECT systems, the boiler might not be working. Check the boiler operation, and if a fault is suspected, consult the boiler manufacturer's instructions. * For INDIRECT systems, the thermal cut-out may have operated. Check and reset it by pushing the button on the cut-out. Also, check the operation of the indirect thermostat. * For INDIRECT systems, the motorized valve might not be ...

Summary

Installation - General

Pipe Fittings

Details connection types and sizes for plumbing fittings.

Cold Feed

Specifies requirements for the cold water supply connection.

Installation - Discharge

G3 Requirement

Outlines Building Regulation G3 requirements for discharge safety.

Discharge Pipe D1

Specifies requirements for the discharge pipe from safety devices to the tundish.

Tundish

Details the placement and requirements for the tundish.

Discharge Pipe D2

Specifies requirements for the discharge pipe from the tundish.

Installation - Primary Circuit

Commissioning

Filling the Unit with Water

Step-by-step instructions for filling the unit with water.

System Checks

Procedures for checking system connections and components.

Indirect (Primary) Circuit

Guidance on filling and checking the primary heating circuit.

Maintenance

Safety Valve Operation

Instructions for testing safety valves and checking discharge.

User Instructions

Warnings

Critical safety warnings for users regarding operation and safety valves.

Fault Finding & Servicing

Guarantee

Warning

Warns about tampering with relief valves invalidating the guarantee.

Commissioning Check List

Service Record