PRE-PLUMBED UNVENTED MAINS PRESSURE WATER HEATER
120, 150, 170, 210, 250 and 300 LITRE CAPACITY INDIRECT MODELS
INSTALLATION AND SERVICING INSTRUCTIONS
IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS
BEFORE COMMENCING INSTALLATION. PLEASE LEAVE THIS MANUAL
WITH THE CUSTOMER FOR FUTURE REFERENCE.

Questions and Answers

  • D
    dayhaleyAug 8, 2025
    What to do if Santon Premier Plus 210 Water Heater discharges from T&P Relief Valve?
    • B
      Brandon MortonAug 8, 2025
      If your Santon Water Heater is discharging from the T&P Relief Valve, it could be due to thermal control failure, and the water will be very hot. Switch off power to immersion heater(s) and/or shut down the boiler. Do not turn off the water supply. After the discharge stops, check all thermal controls, and replace them if faulty.
  • K
    Katie SimsAug 20, 2025
    What to do if Santon Premier Plus 210 Water Heater discharges from Expansion Valve?
    • J
      John KleinAug 20, 2025
      If your Santon Water Heater is discharging from the Expansion Valve, it could be due to: * INTERMITTENTLY: The expansion vessel charge pressure has reduced below 3.5 bar. See the Maintenance section for the re-charging procedure. * CONTINUALLY: This could be due to a cold water combination valve pressure reducer not working correctly or an expansion valve seat damaged. * Check the pressure from the cold water combination valve. If it's greater than 3.6 bar, replace the pressure reducer cartridge. * Remove the expansion valve cartridge and check the condition of the seat. If necessary, fit a new expansion valve cartridge.
  • C
    choistephanieAug 26, 2025
    How to fix no hot water flow in Santon Premier Plus 210?
    • C
      cindy83Aug 26, 2025
      If there is no hot water flow from your Santon Water Heater, the possible causes and solutions are: * Mains supply off: Check and open the stock cock. * Strainer blocked: Turn off the water supply, remove the strainer, and clean it. * Cold water combination valve incorrectly fitted: Check and refit as required.
  • C
    Christopher HernandezSep 1, 2025
    Why is my Santon Water Heater water milky?
    • T
      taylordanielSep 1, 2025
      If the water from your Santon Water Heater appears milky, it is likely due to oxygenated water. Water from a pressurized system releases oxygen bubbles when flowing, causing the milkiness. This will disappear after a short while.
  • S
    Steven FowlerNov 13, 2025
    Why is water from hot taps cold in my Santon Water Heater?
    • T
      Timothy ScottNov 13, 2025
      If the water from your hot taps is cold, several issues could be the cause: * The BACK UP immersion heater might not be switched on. Check and switch it on. * The BACK UP immersion heater thermal cut-out may have operated. Check and reset it by pushing the button. * For INDIRECT systems, the programmer might be set to Central Heating only. Check and set it to the Domestic Hot Water program. * For INDIRECT systems, the boiler might not be working. Check the boiler operation, and if a fault is suspected, consult the boiler manufacturer's instructions. * For INDIRECT systems, the thermal cut-out may have operated. Check and reset it by pushing the button on the cut-out. Also, check the operation of the indirect thermostat. * For INDIRECT systems, the motorized valve might not be ...

Summary

The Benchmark Scheme Overview

Introduction to PremierPlus SystemFit

General Installation Requirements

Component Check List

Lists all components supplied with the PremierPlus SystemFit unit for installation.

Siting the Unit Guidelines

Guidelines for vertically mounting the unit, considering floor strength and access.

Water Supply Requirements

Details recommended water supply pressure and flow rates for optimal performance.

Operational Specs, Limitations & Fittings

Outlet and Terminal Fittings

Information on compatible fittings and pipework for the unit's outlets.

System Limitations

Lists applications and situations where the PremierPlus SystemFit should not be used.

Operational Summary Data

Key technical parameters and operating limits for the PremierPlus SystemFit unit.

Outline Specifications

Details materials, insulation, and pipe connection specifications of the unit.

Dimensions and Performance Data

Key Component Technical Details

Danfoss TP9000 Programmer Details

Features and specifications of the programmable thermostat for DHW control.

Honeywell Motorised Valve Specifications

Specifications for the 2-port motorised valves used in the system.

Automatic Bypass Valve Details

Details the automatic differential bypass valve model and settings.

Primary Circulating Pump Performance

General Installation Procedures

Pipe Fittings and Connections

Specifies connection types, sizes, and recommended fittings for installation.

Cold Feed Requirements

Details the requirements for the cold water supply connection.

Pressure Reducing Valve Installation

Explains the function and positioning of the 3.5 bar pressure reducing valve.

Expansion Vessel Connection

Describes the role and connection of the expansion vessel for heating water.

Tundish Placement

Specifies tundish placement and air gap requirements for safe discharge.

Additional General Installation Details

Drain Taps Usage

Instructions for using drain taps for maintenance and draining purposes.

Hot Water Outlet Pipework

Guidance on pipework for hot water outlets from the unit.

Secondary Circulation System

Details on connecting and requirements for a secondary circulation system.

Discharge Pipe Installation Requirements

Building Regulation G3 Discharge Requirements

Outlines Building Regulation G3 requirements for conveying discharges safely.

Discharge Pipe Types D1 and D2

Details specifications for discharge pipes D1 (to tundish) and D2 (from tundish).

Tundish Installation Details

Specifies tundish placement, air gap, and visibility for safe discharge.

Discharge Pipe Sizing and Safety

Discharge Pipe Sizing Examples

Provides worked examples for correctly sizing discharge pipes based on regulations.

Discharge Pipe Safety Warnings

Lists critical warnings regarding discharge pipe installation and tampering.

Primary Circuit Installation Guide

Boiler Selection Criteria

Guidance on choosing compatible boilers for the PremierPlus SystemFit unit.

Indirect Thermal Cut-out and 2-Port Valve

Explains the function and importance of these safety components.

Electrical Wiring Guidelines

Instructions for electrical wiring to be carried out by a competent electrician.

Heating System Controls Configuration

Details on connecting and configuring heating system controls.

Programmer and Room Temperature Sensor

System Commissioning Steps

Filling the Unit with Water

Step-by-step guide for filling the unit with water and purging air.

System Checks Procedure

Procedures for checking connections, relief valves, and strainer.

Primary Circuit Commissioning

Steps for filling, checking, and commissioning the primary heating circuit.

Routine Maintenance Procedures

Automatic System By-Pass Adjustment

Explains how to adjust the automatic differential bypass valve for optimal performance.

Maintenance Requirements and Schedule

General requirements and frequency for maintaining the unvented system.

Internal Inspection Procedure

Guidance on inspecting the cylinder internally via the immersion heater boss.

Safety Valve Operation Check

Procedure for manually operating and checking safety valves.

Strainer Cleaning

Steps for cleaning the strainer element in the pressure reducing valve.

Descaling Immersion Heaters

Instructions for draining and descaling immersion heaters.

Post-Maintenance Procedures

Immersion Heater Removal and Replacement

Detailed steps for safely removing and replacing immersion heaters.

Expansion Vessel Charge Pressure Check

How to check and adjust the expansion vessel's pressure.

Re-commissioning After Maintenance

Steps to follow after maintenance or if the system needs re-commissioning.

Benchmark Log Book Completion

Requirement to complete the log book for maintenance and servicing records.

User Operation and Safety Guidance

Critical User Warnings

Critical safety warnings for users regarding system faults and safety valves.

Understanding the Benchmark Scheme

Explanation of the Benchmark Scheme and its importance for users.

System Operation and Performance Details

Temperature Control Adjustments

Details on setting and adjusting thermostats for immersion heaters and boilers.

Boiler Heating Integration

Explains how the boiler interacts with the indirect heating system.

Flow Performance Characteristics

Describes normal flow characteristics and potential visual aspects of hot water.

Troubleshooting Operational Faults

Overview of common faults and their potential causes.

Troubleshooting and Servicing Guide

Important Servicing Precautions

Key points and precautions before performing maintenance or servicing.

Fault Finding Table

A table listing common faults, their causes, and remedies.

Spare Parts Information

Information on obtaining authorized spare parts for the unit.

General Fault Diagnosis

Advice on identifying and rectifying operational faults.

Servicing Safety Warnings

Critical warnings related to safety and guarantees during servicing.

Guarantee and Environmental Information

Guarantee Validity Warnings

Warning about tampering with safety valves invalidating the guarantee.

Guarantee Terms and Conditions

Details the duration and conditions of the product guarantee.

Environmental Impact

Benchmark Commissioning Checklist

Maintenance Service Record

Official Spares Stockists

Santon Premier Plus 210 Specifications

General IconGeneral
Capacity210 Litres
Diameter550 mm
Power Rating3 kW
Voltage230 V
Minimum Working Pressure1.5 bar
Protection RatingIPX4
TypeUnvented
Warranty25 Years