EasyManua.ls Logo

Santon Premier Plus 210 - Key Component Technical Details; Danfoss TP9000 Programmer Details; Honeywell Motorised Valve Specifications; Automatic Bypass Valve Details

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Danfoss TP9000 Programmable thermostat with timed Domestic
Hot Water (DHW) control:
Programmer dimensions: 135mm (W) x 88mm (H) x 32mm (D)
Room temperature sensor dimensions: 60mm (W) x 45mm (H) x 21mm (D)
Power supply: 220V/240V ac, 50Hz
Switch action 2 x SPDT, Type 1B. Switch rating 220/240V ac, 50/60Hz, 3(1)A
Power reserve: Minimum 24 hours
Memory back up retained for life of product
Enclosure rating: IP30
Control temperature range: Selectable 5 to 30°C
Holiday mode with room temperature setback
Timing accuracy: +/- 1 minute/month
Maximum ambient temperature: 45°C
Honeywell 2 Port motorised valves:
Model No.: V4043H
Voltage rating: 230V ac, 50HZ
Power consumption: 6W
Primary water temperature range: 5 to 88°C
Maximum ambient temperature: 52°C
Automatic differential by-pass valve:
Model No.: RWC DIFF 200 005
Setting range: 0 to 0.05 MPa (0 to 0.5 bar) differential pressure
Maximum primary water temperature: 110°C
Maximum operating pressure 1.0MPa (10 bar)
Graph 1 - Bypass valve pressure vs volume