OUTLET/TERMINAL FITTINGS (TAPS, ETC.)
The PremierPlus SystemFit can be used in conjunction with most types of terminal ttings, plumbing ttings and pipework.
However, the rated pressures of any ttings selected should be checked for compatibility before installation.
NOTE: Accessories, plumbing ttings and pipework should have a rated operating pressure of at least 6 bar.
Outlets situated higher than the PremierPlus SystemFit unit will give outlet pressures lower than that at the heater, a
10m height difference will result in a 1 bar pressure reduction at the outlet tting.
LIMITATIONS
The PremierPlus SystemFit cylinder should not be used in association with any of the following:
Solid fuel boilers or any other boiler in which the energy input is not under effective thermostatic control, unless additional
and appropriate safety measures are installed.
Ascending spray type bidets or any other class 1 back syphonage risk require that a type A air gap be employed.
Steam heating plants unless additional and appropriate safety devices are installed.
Situations where maintenance is likely to be neglected or safety devices tampered with.
Water supplies that have either inadequate pressure or where the supply may be intermittent.
Situations where it is not possible to safely pipe away any discharge from the safety valves.
In areas where the water consistently contains a high proportion of solids, e.g. suspended matter that could block the
strainer unless adequate ltration can be ensured.
OPERATIONAL SUMMARY
Maximum PremierPlus pressure 16 bar
Operating pressure 3.5 bar
Expansion vessel pressure 3.5 bar
Expansion relief valve setting 6 bar
T&P relief valve setting 90°C/10 bar
Maximum primary circuit pressure 3 bar
Pressure drop (primary coil) 0.02MPa (0.02 bar)
Storage capacity See Table 1 below
Weight when full See Table 1 below
OUTLINE SPECIFICATIONS
Outer casing: White textured plastic coated corrosion resistant steel
Water container: Duplex stainless steel. 100% pressure tested to 1.5 MPa (15 bar).
Thermal insulation: CFC/HCFC free re retardant expanded polyurethane foam with zero ozone depletion potential. It has
a Global Warming Potential (GWP) of 3.1. Nominal thickness 50mm.
Pipe connections: All connections accept 22mm outside diameter pipe – compression nuts and olives supplied. Thread rate
is 3/4” BSP male parallel to accept standard 3/4” BSP female ttings if required.
Table 1 - Unit Weights & Standing Heat Loss
Nominal Capacity
(litres)
Weight of full unit
(kg)
Weight of unit (kg)
Standing Heat Loss
per day (kWh/24h) per year kWh/365d)
120 159 39 1.25 456.3
150 196 43 1.45 529.3
170 215 45 1.63 595.0
210 263 53 1.91 697.2
250 312 62 2.22 810.3
300 372 72 2.52 919.8