I - 82
SM830082
1
2
3
4
5
1. Specifications
1-9 Performance Charts
Heating Characteristics
(1) Operating Current
11
11
1 Indoor Unit: UH2442 Outdoor Unit: CH2442
Operating current characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V 208V
230V 208V
Indoor Unit: UH3642 Outdoor Unit: CH3642
2194_X_S
Operating current (A)
75 (24)
70 (21)
65 (18)
13
14
15
9
8
10
11
12
14 23 41 50 59 68
(–10) (–5)
32
( 0 ) ( 5 ) (10) (15) (20)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
2195_X_S
Operating current (A)
75 (24)
70 (21)
65 (18)
13
14
15
9
8
10
11
12
14 23 41 50 59 68
(–10) (–5)
32
( 0 ) ( 5 ) (10) (15) (20)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
2233_X_S
Operating current (A)
20
21
22
16
15
17
18
19
14 23 41 50 59 68
(–10) (–5)
32
( 0 ) ( 5 ) (10) (15) (20)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
75 (24)
70 (21)
65 (18)
2234_X_S
Operating current (A)
14 23 41 50 59 68
(–10) (–5)
32
( 0 ) ( 5 ) (10) (15) (20)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
75 (24)
70 (21)
65 (18)
20
21
22
16
15
17
18
19

Table of Contents