-27-
Adjustments
Group/
Item
Item Name Function Initial Range Note
21 Test Pattern
0: Off 1: Color Ramp
2: Color Bar 3: 16 step
4: Grid 5: Green Grid
6: 1-line Pattern 7: 1-dot Pattern
8: BC Calibration 9: Half Cross
0 0 - 9
Group 155 CCA
0 CCA Disable 0: CCA Enable, 1: Disable 0 0 - 1
Group 156 Color Matching - Measured Data
0 Measured Red -X
Adjust Color matching Data
0: Image = Dynamic mode
1: Image = Standard mode
2: Image = Cinema mode
3: 120Hz Output mde
4: 3D mode
* This data will be effective after executing the
item 100.
0 - 1000
1 Measured Red -Y 0 - 1000
2 Measured Red -Luma 0 - 32767
10 Measured Green -X 0 - 1000
11 Measured Green -Y 0 - 1000
12 Measured Green -Luma 0 - 32767
20 Measured Blue -X 0 - 1000
21 Measured Blue -Y 0 - 1000
22 Measured Blue -Luma 0 - 32767
70 Measured Full White -X 0 - 1000
71 Measured Full White -Y 0 - 1000
72 Measured Full White -Luma 0 - 32767
100 measured Data Update
Update the Measured Data when the value is
set to 10.
0 - 10
120 Measured Test Pattern OFF / Red / Green / Blue / Full White 0 - 4
Group 160 Waveform Index
0 Bright Image Mode Image = Dynamic 0 0 - 10
1 Normal Image Mode Image = Standard 0 0 - 10
2 Color Image Mode Image = Cinema 0 0 - 10
3 Normal 120Hz 120Hz Mode 0 0 -10
4 3D Image Mode 3D Mode 0 0 - 10
Group 161 Lamp Sync Delay
0 Bright Image Mode Image = Dynamic 190 0 - 32767
1 Normal Image Mode Image = Standard 190 0 - 32767
2 Color Image Mode Image = Cinema 190 0 - 32767
3 Normal 120Hz 120Hz Mode 190 0 - 32767
4 3D Image Mode 3D Mode 190 0 - 32767
Group 200 Option
0
Logo Prohibition (Forced No Brand)
Logo Prohibition (0: Menu, 1: Forced, 2: China,
3-9: not used) Effective after AC On
0 0 - 2
1 RS232C Baudrate Baud Rate 0: 19200bps, 1: 9600bps 0 0 - 1
4 CABLE SW Long Cable 0: Disable, 1: Enable 0 0 - 1
5 PW Debug Command Enable
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
0 0 - 1
8 Network Hung up Check 0: Enable, 1: Disable 0 0 - 1
51 Filter Warning Display Filter Waring Display On/Off 0: Off, 1: On 1 0 - 1
53 Filter Counter Reset Times Reset Times 0 0 - 255
54 Factory Default Execute Times Reset Times 0 0 - 255
63 Source Search Enable Siurce Search Enable o: Disable, 1: Enable 1 0 - 1
80 Destination Setting Shipping Destination 0: English, 1: Japanese 0 0 - 1
111 Sound Mute 0: work alone, 1: Work with Video Mute 1 0 - 1
120 HDMI CONT
0: EDID/HPD Manual Control in the Standby
1: EDID/HPD Auto Control in the Standby
1 0 - 1
Group 201 Option (signal)
0 VSBEG 8 0 - 255
Group 220 Error Log
0 Waring Log 1 Latest Error Log 0 0 - 32767
~ Warning Log x th x th old Error Log 0 0 - 32767
49 Warinig Log 50 50th old Error Log 0 0 - 32767
50 Warinig Log Reset
Resets All Warning Logs when the value is set
to 10.
0 0 - 10
Group 250 FAN Voltage Adjustment
0 Fan1 Min. Adjust (DAC) 25 0 - 255
1 Fan1 Max. Adjustt(DAC) 235 0 - 255
2 Fan2 Min. Adjust (DAC) 27 0 - 255
3 Fan2 Max. Adjust (DAC) 237 0 - 255