-29-
Adjustments
Group/
Item
Item Name Function Initial Range Note
Group 254 FAN Control Range Setting (Temp./Voltage)
L1
Normal
L2
Ceiling
L3
Bottom
L4
Up
0 Normal Fan Control Min. Temp Temp Sensor Control Start/End at Normal 27 27 27 27 20 - 100
1 Normal Fan Control Max. Temp 36 36 36 36 20 - 100
2 Normal Fan1 Min. Fan Voltage at Normal (x0.1V) 62 62 62 62 0 - 255
3 Normal Fan1 Max. 138 138 138 138 0 - 255
4 Normal Fan2 Min. 90 70 105 55 0 - 255
5 Normal Fan2 Max. 95 70 110 70 0 - 255
6 Normal Fan3 Min. 75 95 55 115 0 - 255
7 Normal Fan3 Max. 75 105 75 120 0 - 255
8 Normal Fan4 Min. 80 80 80 80 0 - 255
9 Normal Fan4 Max. 138 138 138 138 0 - 255
10 Normal Fan5 Min. 75 78 78 75 0 - 255
11 Normal Fan5 Max. 138 138 138 138 0 - 255
12 Normal Fan6 Min. 55 55 55 55 0 - 255
13 Normal Fan6 Max. 135 135 135 135 0 - 255
16 Eco Fan Control Min. Temp Temp Sensor Control Start/End at Eco 27 27 27 27 20 - 100
17 Eco Fan Control Max. Temp 37 37 37 37 20 - 100
18 Eco Fan1 Min. Fan Voltage at Eco (x0.1V) 60 60 60 60 0 - 255
19 Eco Fan1 Max. 70 70 70 70 0 - 255
20 Eco Fan2 Min. 60 50 60 45 0 - 255
21 Eco Fan2 Max. 70 55 70 50 0 - 255
22 Eco Fan3 Min. 50 65 50 65 0 - 255
23 Eco Fan3 Max. 55 75 55 75 0 - 255
24 Eco Fan4 Min. 60 60 60 60 0 - 255
25 Eco Fan4 Max. 120 120 120 120 0 - 255
26 Eco Fan5 Min. 52 55 55 52 0 - 255
27 Eco Fan5 Max. 110 110 110 110 0 - 255
28 Eco Fan6 Min. 50 50 50 50 0 - 255
29 Eco Fan6 Max. 115 115 115 115 0 - 255
Group 255 FAN Start/Cooling Setting
0 Fan1 Initial Volt Fan Voltage at Startup (x0.1V) 70 0 - 255
1 Fan2 Initial Volt 60 0 - 255
2 Fan3 Initial Volt 60 0 - 255
3 Fan4 Initial Volt 65 0 - 255
4 Fan5 Initial Volt 70 0 - 255
5 Fan6 Initial Volt 60 0 - 255
7 Cooling Time L1 Cooling Time at L1 (x 30 sec.) 2 1 - 15
8 Cooling Time L2 Cooling Time at L2 (x 30 sec.) 3 1 - 15
9 Temp Error Cooling Time Cooling Time at Temp Error (x 30sec.) 3 1 - 15
10 onStart Cooling Start Threshold Cooling Start Threshold Temp at On Start 46 0 - 100
11 After Shutdown Cooling Cooling On/Off After Shutdown 1 0 - 1
12 L1 Cooling Volt Fan2 Cooling Fan Voltage at L1 (x0.1V) 40 0 - 255
13 L1 Cooling Volt Fan3 40 0 - 255
14 L1 Cooling Volt Fan4 60 0 - 255
Group 259 FAN Atmosphere Setting
10
Temp A Warning (Normal, High-
Land ON1)
Temperature A to judge the Temp. Failure
Outside at Normal and HighLand ON1
42 0 - 100
11
Temp B Warning (Normal, High-
Land ON1)
Temperature B to judge the Temp. Failure DMD
at Normal and HighLand ON1
62 0 - 100
12
Temp C Warning (Normal, High-
Land ON1)
Temperature C to judge the Temp. Failure Lamp
at Normal and HighLand ON1
62 0 - 100
13
Temp A Warning (Eco, HighLand
ON1)
Temperature A to judge the Temp. Failure
Outside at Eco and HighLand ON1
42 0 - 100
14
Temp B Warning (Eco, HighLand
ON1)
Temperature B to judge the Temp. Failure DMD
at Eco and HighLand ON1
61 0 - 100
15
Temp C Warning (Eco, HighLand
ON1)
Temperature C to judge the Temp. Failure Lamp
at Eco and HighLand ON1
64 0 - 100
16
Temp A Warning (Normal, High-
Land ON2)
Temperature A to judge the Temp. Failure
Outside at Normal and HighLand ON2
37 0 - 100
17
Temp B Warning (Normal, High-
Land ON2)
Temperature B to judge the Temp. Failure DMD
at Normal and HighLand ON2
58 0 - 100
18
Temp C Warning (Normal, High-
Land ON2)
Temperature C to judge the Temp. Failure Lamp
at Normal and HighLand ON2
53 0 - 100
19
Temp A Warning (Eco, HighLand
ON1)
Temperature A to judge the Temp. Failure
Outside at Eco and HighLand ON2
59 0 - 100
20
Temp B Warning (Eco, HighLand
ON1)
Temperature B to judge the Temp. Failure DMD
at Eco and HighLand ON2
38 0 - 100
21
Temp C Warning (Eco, HighLand
ON1)
Temperature C to judge the Temp. Failure Lamp
at Eco and HighLand ON2
58 0 - 100
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
Executes Auto-Calibration when the value is set
to1
0 0 - 1