-25-
Mechanical Disassembly
4-1. Filter Box Assy and Fans removal
1. Remove 4 screws-A (T3x8) and 1 screw-B(M3x6) and take the Filter Box
Assy upward off.
2. Remove 2 screws-C (T3x10) and pull the Fans Assy upward off.
A
A
Filter cartridge
Filter box assy
M3x8
M3x8
M3x8
T3x16
T3x8
T3x8
T3x8
T3x8
Wind sensor
(S901)
C
Filter motor
Filter SW board
Round sensor
board
FN905
FN904
B